| Plan Review Notes For Permit 10080605 |
| Permit Number |
10080605 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2010-08-23 11:11:51 | RESIDENTIAL (R3) RE-ROOF CHECKLIST. | | | 2007 FBC WITH 2009 REVISIONS. | | | | | | 1- FLAT ROOF: | | | A) PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR | | | NAIL ENHANCING AT PERIMETER AND CORNER AREAS AS | | | REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF NOA | | | 09-0224.01 SUBMITTED. | | | NAIL ENHANCING REQUIRED TO MEET THE DESIGN PRESSURES OF | | | SEC. R301 OF 2007 FLORIDA RESIDENTIAL CODE. | | | | | | B) IDENTIFY WHICH BASE SHEET FASTENING OPTION ON SHEET | | | 29 OF NOA SUBMITTED IS GOING TO BE USED. | | | | | | 2- SPECIFY HOW MUCH FLAT ROOF AREA AND HOW MUCH PITCHED | | | AREA IS GOING TO BE INSTALLED TO CHECK PERMIT VALUATION | | | AS REQUIRED BY SEC. 108.3 CITY AMENDMENTS TO FBC. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|