2010-08-17 19:26:49****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. ARCHITECTURAL SHEET A3 DOES NOT MATCH MECHANICAL
 FLOOR PLAN, SEE MASTER BEDROOM.
  
 2. PROVIDE THE TOTAL SQUARE FOOT AREA UNDER AIR
 PROPOSED. IMPACT FEES MAY BE DUE TO PALM BEACH COUNTY,
 233-5025. THE PLANS ARE TO BE STAMPED AND THE RECEIPT
 (IF FEES ARE DUE) PROVIDED.
  
 3. THIS PARCEL IS LOCATED IN A FLOOD ZONE. FINISHED
 FLOOR IS REQUIRED TO BE 6" ABOVE BFE (WPB ADMIN CODE
 94-546(B)*.
  
 4. PROVIDE A SIGNED AND SEALED FLOOD ELEVATION
 CERTIFICATE FOR THE PROPOSED CONSTRUCTION
 (HTTP://WWW.FEMA.GOV/BUSINESS/NFIP/ELVINST.SHTM). THREE
 ELEVATION CERTIFICATES WILL REQUIRED; PRE CONSTRUCTION,
 FORM BOARD, AND FINISHED FLOOR.
  
 5. PROVIDE A COST BREAKDOWN OF THE PROPOSED
 IMPROVEMENT. AS PROPOSED ELEVATIONS WERE NOT PROVIDED,
 AND A COST BREAKDOWN (ADDITION VS. RENOVATION AREAS) IT
 IS NOT CLEAR WHETHER OR NOT THIS IS A SUBSTANTIAL
 IMPROVEMENT, WPB ADMIN CODE 94-546. SEE ALSO HTTP://WWW
 .FEMA.GOV/PLAN/PREVENT/FLOODPLAIN/NFIPKEYWORDS/SI.SHTM
 FOR MORE INFORMATION.
  
 6. SEE FBC EXISTING BUILDING 401.4, A DESIGN
 PROFESSIONAL OR AN OWNER MUST ELECT ONE OR A
 COMBINATION OF LEVELS OF ALTERATION. PLEASE INCLUDE
 THIS INFORMATION ON THE PLAN. PLEASE REVIEW ALL
 REQUIREMENTS (AND ALSO CH 10, ADDITIONS) AND SHOW
 COMPLIANCE ON THE PLAN.
  
 7. PROVIDE A COPY OF THE SURVEY FOR THIS PARCEL.
  
 8. PRODUCT APPROVAL REQUIRED FOR THE SIDING AND ROOF.
 THE ROOF PRODUCT APPROVAL MAY BE SUBMITTED WITH THE
 ROOF PERMIT.
  
 9. STUCCO IS SHOWN AS 5/8" ON SHEET A8, SEE INSPECTION
 FOR TERMITES 704.1 EXCEPTION 1.
  
 10. PROVIDE ENERGY CALCS, FBC 13-6.
  
 11. SMOKE AND CARBON MONOXIDE ALARMS ARE REFERENCED ON
 E3 BUT NOT SHOWN ON PLAN, PLEASE SHOW ALL REQUIRED ON
 THE PLAN.
  
 12. SEE FS 553.844 REGARDING ROOF MITIGATION
 REQUIREMENTS AND OPENING PROTECTION REQUIREMENTS AND
 SHOW COMPLIANCE ON THE PLAN. CLARIFY SCOPE OF REROOF
 AREA.
  
 13. SEE FBC R301.2.1.4.3 (2), EXPOSURE C: BUILDINGS
 LOCATED WITHIN A DISTANCE OF 600 FEET OF INLAND BODIES
 OF WATER THAT PRESENT A FETCH OF 1 MILE (1.61 KM) OR
 MORE OR INLAND WATERWAYS OR RIVERS WITH A WIDTH OF 1
 MILE (1.61 KM) OR MORE SHALL BE CLASSIFIED AS EXPOSURE
 C AND ROOF SHEATHING UPLIFT AND ROOF-TO-WALL UPLIFT
 LOADS SHALL BE INCREASED BY 20 PERCENT.
  
  