| Date |
Text |
| 2010-09-02 11:40:34 | 600 VILLAGE BOULEVARD |
| | RENEGADES |
| | PERMIT NUMBER 10070434 |
| | |
| | |
| | 1. ON AUGUST 31, 2010, REPRESENTATIVES OF THE FIRE |
| | MARSHAL'S OFFICE MET WITH PETE RUSSO, ARCHITECT TO |
| | DISCUSS EXITING ISSUES FOR THE ESTABLISHMENT. A NEW |
| | LIFE SAFETY PLAN WAS SUBMITTED LATER IN THE DAY ON |
| | AUGUST 31, 2010 WHICH DISPLAYED NEW EXIT SIGNS AND |
| | EMERGENCY LIGHTS AND ALSO A NEW EXIT OPENING HAS BEEN |
| | PROVIDED FOR NEAR BAR # 2. ALSO DOORS HAVE BEEN REMOVED |
| | APPROACHING THE HOST STAND WHICH APPEARS TO ACCOMMODATE |
| | THE 2/3 REQUIRED EXIT CAPACITY FOR THE ESTABLISHMENT. |
| | |
| | 2. AS NOTED ON THE NEW LIFE SAFETY PLAN, SEPARATE PLANS |
| | AND PERMITS REQUIRED FOR THE FIRE SPRINKLER, FIRE |
| | ALARM, HOOD SUPPRESSION, AND GREASE HOOD EXHAUST |
| | SYSTEMS. |
| | |
| | 3. CROWD MANAGEMENT CERTIFICATES FROM MANAGEMENT |
| | PERSONNEL ARE TO BE SUBMITTED TO THE FIRE MARSHAL'S |
| | OFFICE PRIOR TO OPENING. |
| | |
| | 4. THE MAXIMUM OCCUPANT LOAD WILL BE ESTABLISHED BY THE |
| | FIRE MARSHAL'S OFFICE AND SHALL BE POSTED. THIS LEGAL |
| | OCCUPANT LOAD IS NOT TO BE EXCEEDED FOR ANY REASON. |
| | |
| | 5. WHEN THE FIRE ALARM SYSTEM SHOP DRAWINGS ARE |
| | SUBMITTED, PLEASE INDICATE ON THESE PLANS WHAT |
| | EMERGENCY INSTRUCTIONS WILL BE PROVIDED TO OCCUPANTS. |
| | |
| | 6. ALL EXIT DOORS THAT ARE SUBJECT TO LOADS OF 100 OR |
| | MORE PERSONS SHALL BE EQUIPPED WITH PANIC HARDWARE. |
| | |
| | 7. THE LIGHTING PLAN SHEET 2.0E WILL NEED TO BE CHANGED |
| | TO MATCH THE REVISED LIFE SAFETY PLAN. |
| | |
| | 8. GAS INSTALLATIONS SHALL COMPLY WITH THE APPLICABLE |
| | NFPA STANDARDS AND BE INSTALLED IN A SAFE AND |
| | WORKMANLIKE MANNER. |
| | |
| | |
| | APPROVED PROVISO |
| | |
| | |
| | |
| | MIKE CARSILLO, BATTALION CHIEF |
| | BUREAU OF FIRE PREVENTION |
| | |
| | |
| | |