2010-07-12 10:22:48BUILDING PLAN REVIEW
 PERMIT: 10070015
 ADD: 2870 EAGLE LANE
 CONT: HURRICANE PROOF
 TEL: (561)400-4641
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PLEASE REVIEW THE DESIGN WIND LOAD FORM FROM
 KNEZEVICH NOTE #9 INDICATES THESE DRAWINGS ARE NOT BE
 BE USED FOR PERMIT WITHOUT ORIGINAL SIGNATURE, DATE AND
 SEAL.
 PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS
 PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR
 PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE
 DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT.
 FL ADMIN CODE 61G15-23.002 ENGINEERS
  
 2) THE WIND DESISGN SHEET FROM KNEZEVICH INDICATES THE
 CORNER ZONE (ZONE # 5) TO BE A MINIMUM OF (3'-0") WIDE.
 WINDOW / SHUTTER UNITS ( 1,3, 6 & 9) APPEAR TO BE IN
 THE END ZONE WITH HIGHER ASSOCIATED PRESSURES. ZONE # 5
 IS NOT HIGH LIGHTED FOR ANY OPENINGS. PLEASE INDICATE
 TTHE DIMENSION FROM THE END OF SHUTTER TO CORNER OF
 BUILDING TO VERIFY THAT THESE UNITS ARE NOT LOCATED
 WITHIN A END ZONE. 1609.1.2 COMPONENTS AND CLADDING.
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP