2010-06-23 20:38:00****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. PLEASE EXPLAIN, PLAN SHOWS INSULATION ON INTERIOR
 WALLS WITH VAPOR BARRIER. VAPOR BARRIER IS NOT
 TYPICALLY USED IN INTERIOR WALLS DUE TO MOISTURE
 ISSUES. PLEASE PROVIDE DOCUMENTATION FROM THE
 MANUFACTURER WHICH SHOWS THAT THIS IS ACCEPTABLE.
  
 2. INSULATION IS TYPICALLY INSTALLED IN ADJACENT WALLS
 (WALLS BETWEEN CONDITIONED AND UNCONDITIONED SPACE),
 EXTERIOR WALLS, AND CEILINGS. PLAN SHOWS INSULATION TO
 BE INSTALLED ON INTERIOR WALLS. PLEASE EXPLAIN.
  
 3. HOW WILL THE BATT INSULATION BE INSTALLED? OUR
 RECORDS DO NOT SHOW EVIDENCE OF A PERMIT TO REMOVE OR
 INSTALL DRYWALL. THIS MAY BE ADDED TO THE SCOPE OF WORK
 FOR THIS PERMIT (AND ALSO REVISE VALUE).
  