| Plan Review Notes For Permit 10060348 |
| Permit Number |
10060348 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2010-06-29 13:32:32 | BUILDING PROVISO: | | | BUILDING PROVISO: R703.6.3 WHERE CEMENT PLASTER | | | (STUCCO) IS TO BE APPLIED TO LATH OVER FRAME | | | CONSTRUCTION, MEASURES SHALL BE TAKEN TO PREVENT | | | BONDING BETWEEN THE CEMENT PLASTER AND THE | | | WATER-RESISTIVE BARRIER. A BOND BREAK SHALL BE PROVIDED | | | BETWEEN THE WATER-RESISTIVE BARRIER AND THE CEMENT | | | PLASTER (STUCCO) CONSISTING OF ONE OF THE FOLLOWING: | | | 1. TWO LAYERS OF AN APPROVED WATER-RESISTANT BARRIER | | | MATERIAL; OR | | | 2. ONE LAYER OF AN APPROVED WATER-RESISTANT BARRIER | | | OVER AN APPROVED PLASTIC HOUSE WRAP; OR | | | 3. OTHER APPROVED METHODS OR MATERIALS APPLIED IN | | | ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS. | | | |
|