Plan Review Notes
Plan Review Notes For Permit 10060315
Permit Number 10060315
Review Stop B
Sequence Number 1
Notes
Date Text
2010-06-21 10:46:59BUILDING PLAN REVIEW
 PERMIT: 10060315
 ADD: 3800 WASHINGTON SUITE 608
 CONT: GLENDON CONST INC
 TEL: (239)860-2678
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 BUILDING PROVISO:
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED
 DEFICIENCIES IN THIS PLAN PRIOR TO INSPECTION WILL
 RESULT IN FAILED INSPECTION(S)
 AND THE ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS
 REQUIRE ADDITIONAL
 REVIEWS WITH ASSOCIATED FEES.
  
 THE PERMIT APPLICATION INDICATES THE INSTALATION OF
 FLOOR TILE. PLANS ARE LACKING
 FLOOR INSULATION REQUIREMENT SEE FBC-B 1207.3
 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND
 A PUBLIC OR SERVICE AREA WITHIN THE STRUCTURE SHALL
 HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE
 WITH ASTM E 492.
  
  
  