2010-06-24 15:47:00REVIEW #: 1ST
 ACTION: DENIED
  
 FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 PROVIDE VENTILATION CALCULATIONS FOR ALL RECONFIGURED
 SPACES WITHIN THE WORK AREA IN ACCORDANCE WITH FBC-EB
 709.1 AND FBC-M 403.3. INCLUDE SPACE-BY-SPACE
 CALCULATIONS FOR OCCUPANCY CLASSIFICATION, OCCUPANT
 LOAD AND VENTILATION RATES IN ACCORDANCE WITH FBC-M
 TABLE 403.3.
  
 NOTE: COMMERCIAL KITCHEN EXHAUST/VENTILATION SYSTEM IS
 NOT PART OF THE SCOPE FOR THIS REVIEW. SEPARATE PLANS
 AND PERMIT APPLICATIONS ARE REQUIRED FOR HOOD SYSTEMS,
 SUPPRESSION SYSTEMS AND WALK-IN COOLERS.
  