| Plan Review Notes For Permit 10050706 |
| Permit Number |
10050706 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2010-05-26 09:52:54 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW CHECKLIST. | | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | | | 1- ENGINEER CALCULATIONS SUBMITTED DON'T COMPLY WITH | | | SEC. 8.1 OF ROOFING APPLICATION STANDARD (RAS) 117. THE | | | MINIMUM FASTENER SEPARATION SHALL NOT BE LESS THAN 4 | | | IN. O.C.. ENGINEER CALCULATIONS SHOW 3 IN O.C. SPACING | | | FOR ROOF CORNER AREAS. REVISE AS REQUIRED. | | | | | | 2- ENGINEER FASTENING SPACING FOR PERIMETER AREA | | | SPECIFIES SIDE LAP FASTENER SPACING AT 12 IN. O.C. | | | PRODUCT APPROVAL (NOA 09-0224.01) SUBMITTED SPECIFIES | | | SIDE LAP SPACING AT 9 IN. O.C. FOR FIELD AREA ONLY. | | | REVISE SIDE LAP SPACING FOR PERIMETER AREA AND PROVIDE | | | SIDE LAP NAIL ENHANCING AT PERIMETER AND CORNER AREAS | | | ACCORDINGLY TO RAS 117 CALCULATIONS. | | | | | | 3- ENGINEER TO PROVIDE ALL HIS INFORMATION AND | | | ENGINEERING FIRM CERTIFICATE OF AUTHORIZATION NUMBER AS | | | REQUIRED BY CHAPTER 471 FLORIDA STATUTES AND BY SEC. | | | 61G15-23.002(2) OF FLORIDA ADMINISTRATIVE CODE. NO | | | INFORMATION WAS SUBMITTED. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 |
|