| Plan Review Notes For Permit 10040509 |
| Permit Number |
10040509 |
|
| Review Stop |
FIRE |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2010-05-10 16:43:27 | *****DENIED***** | | | | | | | | | 1. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241 - 2004 | | | EDITION. | | | | | | 2. THE ACTUAL PROJECT SITE ADDRESS, INCLUDING SUITE | | | NUMBER, SHALL BE IN THE TITLE BLOCK OF EACH SUBMITTED | | | PLAN SHEET. | | | | | | 3. SHOW LOCATION OF EXIT LIGHTS, EMERGENCY LIGHTS, AND | | | FIRE EXTINGUISHERS. | | | | | | 4. SPECIFY INTERIOR WALL AND CEILING FINISH MATERIALS | | | FOR THIS NEW ASSEMBLY OCCUPANCY IN TERMS OF CLASS A, | | | CLASS B, OR CLASS C. | | | | | | 5. NO DOOR DETAIL INCLUDED IN PLAN. BE ADVISED - ANY | | | DOOR IN AN REQUIRED MEANS OF EGRESS FROM AN AREA HAVING | | | AN OCCUPANT LOAD OF 100 OR MORE SHALL BE PERMITTED TO | | | BE PROVIDED WITH PANIC HARDWARE OR FIRE EXIT HARDWARE. | | | ONLY APPROVED PANIC HARDWARE SHALL BE USED ON DOORS | | | THAT ARE NOT FIRE DOORS; ONLY APPROVED FIRE EXIT | | | HARDWARE SHALL BE USED ON FIRE DOORS. | | | | | | 6. FOR NEW ASSEMBLY OCCUPANCIES, (AS PER 12.3.5.1 OF | | | NFPA 101 - LIFE SAFETY CODE - FLORIDA 2007 EDITION), | | | WHERE THE OCCUPANT LOAD EXCEEDS 100, THE FOLLOWING | | | ASSEMBLY OCCUPANCIES SHALL BE PROTECTED THROUGHOUT BY | | | AN APPROVED SUPERVISED AUTOMATIC SPRINKLER SYSTEM: (1) | | | DANCE HALLS, (2) DISCOTHEQUES, (3) NIGHTCLUBS OR | | | SIMILAR USAGE, (4) ASSEMBLY OCCUPANCIES WITH FESTIVAL | | | SEATING. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE/HOW THE ABOVE ITEMS ARE | | | ADDRESSED | | | | | | | | | MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|