| Date |
Text |
| 2010-04-27 08:25:25 | BUILDING PLAN REVIEW |
| | PERMIT: 10040509 |
| | ADD: 2250-2260 PALM BEACH LAKES BLVD |
| | CONT: LTL BUILDERS, INC LEONARD TYLKA JR. |
| | TEL: (561)628-9753 |
| | |
| | FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| | W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | DESIGN PROFESSIONAL: LEONARD TYLKA JR.- ARCHITECT |
| | |
| | DATE: 4-27-2010 |
| | |
| | I SPOKE WITH MR TYLKA IN REGARDS TO THE EXISTING TENANT |
| | SEPARATION WALLS ALSO BEING OCCUPANCY SEPARATION |
| | (EXISTING BUILDING 912.5.3) THIS SPACE BEING A A-3 |
| | OCCUPANCY AND MR TYLKA VERIFYING A BUSINESS OCCUPANCIES |
| | ON BOTH SIDES. WE AGREED A (2) HR WALL WOULD BE |
| | REQUIRED (FBC-B TABLE 508.3.3) SINCE THERE IS NO FIRE |
| | SPRINKLERS WITHIN THE BUILDING. A REVISION WILL BE |
| | COMING IN BEFORE THE FRAMING INSPECTION INDICATING HOW |
| | THE 2 HR WALL WILL BE BUILT. |
| | |
| | BUILDING APPROVED WITH EXCEPTION! |
| | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS WILL |
| | REQUIRE ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| | |
| | |
| | JIM WITMER C. B. O. |
| | COMMERCIAL COMBINATION PLAN REVIEW |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE |
| | CUSTOMER SERVICE SURVEY AT: |
| | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| | |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |