| 2010-04-19 14:01:19 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST. | | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | | | 1- IDENTIFY WHICH APPROVED ASSEMBLY IS GOING TO BE | | | INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN | | | PRESSURES OF SEC. R301 OF 2007 FLORIDA RESIDENTIAL | | | CODE. | | | | | | 2-PROVIDE SIGNED AND SEALED CALCULATIONS (2 COPIES) AS | | | REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF NOA | | | SUBMITTED. | | | ***NOTE: APPROVED SYSTEMS WITH GENERAL LIMITATION #9 | | | CAN'T BE USED IN THIS AREA BECAUSE THEY DON'T MEET THE | | | DESIGN PRESSURES OF SEC. R301. | | | | | | 3- DESIGN PROFESSIONAL DON'T THE RAS 117 CALCULATIONS | | | TO CONSIDER THAT ACCORDING TO THE 2009 REVISIONS TO THE | | | 2007 FLORIDA RESIDENTIAL CODE, THIS BUILDING IS LOCATED | | | ON EXPOSURE "C". | | | | | | 4- PROVIDE 2 COPIES OF EACH PRODUCT APPROVAL. ONLY ONE | | | COPY WAS SUBMITTED. | | | | | | 5- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | | FLORIDA STATUTE. | | | | | | 7- FLAT ROOF NOA 07-1203.01 WAS SUPERSEDED BY | | | MIAMI-DADE. GO TO THE MIAMI-DADE WEBSITE AND DOWNLOAD | | | CURRENT NOA. PROVIDE 2 COPIES. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION BUILDING PLANS EXAMINER | | | (561)805-6712 |
|