| 2010-04-07 10:42:11 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2007 |
| | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING |
| | CODE |
| | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007 |
| | FAC FLORIDA ADMINISTRATIVE CODE |
| | FS FLORIDA STATUTE |
| | |
| | 1. FBC11 4.1.2(1), ACCESSIBLE ROUTE FROM THE PUBLIC WAY |
| | REQUIRED. SEE ALSO FBC11 4.1.6(B). |
| | |
| | 2. FBC EB 401.4, A DESIGN PROFESSIONAL MUST ELECT ONE |
| | OR A COMBINATION OF LEVELS OF ALTERATION. |
| | |
| | 3. DOOR 14 IS TO MEET REQUIREMENTS OF FBC11 4.13.6, SEE |
| | ALSO FIGURE 11 25, MANEUVERING CLEARANCE, PULL SIDE |
| | (18IN REQUIRED). |
| | |
| | 4. FBC801.2.2, SHOW COMPLIANCE FOR THE FOAM GAZEBO. |
| | SHOP DRAWINGS WILL ALSO BE REQUIRED AT INSPECTION. |
| | |
| | 5. FBC11 4.15.5 AND FBC 11 FIG 27(A), SEE DETAIL 10 |
| | A5.1, 3.5IN SHOWN FOR DRINKING FOUNTAIN EDGE, 8IN MIN |
| | REQUIRED. IT APPEARS THAT THE SAME DETAIL SERVES FOR |
| | BOTH THE ACCESSIBLE AND NON ACCESSIBLE DRINKING |
| | FOUNTAIN, BUT NOT ALL DIMENSIONS WERE INCLUDED. PLEASE |
| | SEE HEIGHT ON DETAIL 10 A5.1, WHICH IS SHOWN AT TOP OF |
| | FOUNTAIN BUT FIG 27(A) SHOWS DETAIL TO TOP OF SPOUT |
| | FBC11 4.15.2. |
| | |
| | 6. FBC11 4.1.3(10)(B), AT LEAST 50 PERCENT OF DRINKING |
| | FOUNTAINS PROVIDED SHALL COMPLY WITH FBC11 4.15. ONLY |
| | ONE OF THREE IS SHOWN |
| | |
| | 7. FBC 11 FIG 30(E), SPECIFY GRAB BAR LENGTH. PLEASE |
| | NOTE THAT GRAPHICALLY THE SIDE GRAB BARS ARE SHOWN AS |
| | SHORTER THAN THE REAR GRAB BAR ON THE ENLARGED PLAN |
| | DETAIL 1 A5.1 (BUT GRAPHICALLY SHOWN CORRECTLY ON |
| | ELEVATIONS). |
| | |
| | 8. M7.1 STATES THAT MOUNTING OF ROOFTOP EQUIPMENT WILL |
| | BE PERFORMED BY A STRUCTURAL ENGINEER. THIS WILL BE |
| | REQUIRED PRIOR TO INSTALLATION. IF THE EQUIPMENT IS |
| | NEW, STRUCTURAL ENGINEER IS TO ADDRESS ADDITIONAL LOADS |
| | ON THE ROOF STRUCTURE. (PROVISO ITEM, PRIOR TO |
| | INSTALLATION.) |
| | |
| | 9. INFORMATIONAL ONLY, SEPARATE PERMITS REQUIRED FOR |
| | STOREFRONT, EXTERIOR DOORS, OVERHEAD DOORS. |
| | |
| | IF ALL OTHER TRADES PASS REVIEW, A PASSED WITH PROVISO |
| | (REVISION REQUIRED) STATUS CAN BE CONSIDERED. |
| | |
| | |