2010-04-14 09:27:32PROVISO:
 FLOW CONTROL AND VENT SHALL BE INSTALLED PER
 MANUFACTURERS INSTRUCTIONS.
  
 1.GREASE INTERCEPTORS MUST HAVE A VENTED WASTE, SIZED
 IN
 ACCORDANCE WITH CODE REQUIREMENTS FOR VENTING TRAPS,
 TO RETAIN A WATER SEAL AND TO PREVENT SIPHONING.
  
 2. THE FLOW CONTROL DEVICE SHOULD BE INSTALLED IN
 THE WASTE LINE UPSTREAM OF THE GREASE INTERCEPTOR. IT
 SHOULD BE
 PLACED BEYOND THE LAST CONNECTION FROM THE FIXTURE(S)
 AND AS
 CLOSE AS POSSIBLE TO THE UNDERSIDE OF THE LOWEST
 FIXTURE.
  
 REVIEW BY LARRY WAGNER
 CHIEF PLUMBING INSPECTOR