Plan Review Notes
Plan Review Notes For Permit 10030515
Permit Number 10030515
Review Stop B
Sequence Number 1
Notes
Date Text
2010-04-21 08:51:09****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. PLANS ARE TO BE ARCHITECTURAL QUALITY, TO SCALE,
 FBC106. PLANS SUBMITTED DO NOT INCLUDE ENOUGH
 INFORMATION TO DETERMINE CODE COMPLIANCE. IT IS UNCLEAR
 HOW THIS STRUCTURE HAS BEEN DESIGNED TO COMPLY WITH
 REQUIRED LOADS FBCR301.1, SEE FBC R301.2.1.1.
  
 FOR INSTANCE: PLAN STATES "8" DIA CONC PAD", NO
 REINFORCEMENT, NO ANCHORS TO TIE THE FOUNDATION TO THE
 STRUCTURE.
 FOUNDATION PLAN SHOWS "CONC PAD INTO GROUND" WITH NO
 REINFORCEMENT, NO SIZE.\
 HOW HAS IT BEEN DETERMINED THAT THE ROUND FOOTINGS WILL
 BE ADEQUATE TO SUPPORT AND HOLD DOWN THIS STRUCTURE?
 THE WALL SECTION DOES NOT INCLUDE ALL CONNECTORS TO
 SHOW HOW PROPOSED CONSTRUCTION WILL BE STRUCTURALLY
 CONTINUOUS.
 PLANS STATE THERE WILL BE "HAND FRAMED WOOD TRUSSES,"
 HOW WILL THIS BE ACCOMPLISHED? NO DETAILS PROVIDED.
 STUCCO INSTALLATION DOES NOT COMPLY WITH FBC R703.6.3,
 BOND BREAK. NO MINIMUM STUCCO THICKNESS SPECIFIED.
 STATE WIND DESIGN CRITERIA ON THE PLAN - DESIGN MUST
 COMPLY WITH 140MPH EXPOSURE C.
 WALL FRAMING DETAIL FOR OPENING (DOOR)
  
 PLEASE BE ADVISED THAT CONSTRUCTION METHODS WHICH DO
 NOT COMPLY WITH A PRESCRIPTIVE DESIGN METHOD MAY
 REQUIRE CALCULATIONS.
  
 2. CONTRACTOR HAS REQUESTED AN ELECTRIC PERMIT (SEE
 APPLICATION, SIGNED ON "ELECTRICAL CONTRACTOR" LINE).
 NO ELECTRIC WORK SHOWN.
  
 3. PLAN STATES "HAND FRAME" FOR THE DOOR, NO DETAILS
 PROVIDED. CONTRACTOR WILL BE REQUIRED TO DEMONSTRATE
 THAT THE DOOR MEETS THE WIND REQUIREMENTS, BUT THERE IS
 NO PRESCRIPTIVE CODE FOR DOOR CONSTRUCTION. THIS IS
 USUALLY DONE THROUGH A PRODUCT APPROVAL.
  
 4. ROOF PERMIT REQUIRED.
  
 5. SITE PLAN IS TO INCLUDE PROPOSED DIMENSIONS TO
 PROPERTY LINES AND STRUCTURE.
  
  
  