| 2010-03-22 08:50:27 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST. | | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | | | 1-FLAT ROOF: | | | A) MISSING PRODUCT APPROVAL FOR FLAT ROOF. | | | | | | B) CLEARLY MARK WHICH APPROVED ASSEMBLY AND BASE SHEET | | | FASTENING OPTION IS GOING TO BE USED TO VERIFY | | | COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. R301 OF | | | 2007 FLORIDA RESIDENTIAL CODE. | | | | | | C) PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING AT | | | PERIMETER AND CORNER AREAS AS REQUIRED BY GENERAL | | | LIMITATION #7 TO MEET THE DESIGN PRESSURES OF SEC. | | | R301. IF THE GENERAL LIMITATION #7 ON LAST PAGE OF NOA | | | SUBMITTED REQUIRES RAS 117 CALCULATIONS TO BE SIGNED | | | AND SEALED, THEN PROVIDE SIGNED AND SEALED CALCULATIONS | | | (2 COPIES). | | | ***NOTE: DESIGN PROFESSIONAL DOING THE RAS 117 | | | CALCULATIONS TO HAVE INTO CONSIDERATION THAT ACCORDING | | | TO THE 2009 REVISIONS OF THE 2007 FLORIDA RESIDENTIAL | | | CODE, THIS BUILDING IS LOCATED ON EXPOSURE "C". | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 | | | | | | |
|