| Plan Review Notes For Permit 10030028 |
| Permit Number |
10030028 |
|
| Review Stop |
E |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2010-03-10 16:49:24 | 406.11 TAMPER-RESISTANT RECEPTACLES IN DWELLING | | | UNITS. IN ALL AREAS SPECIFIED IN 210.52, ALL 125-VOLT, | | | 15- | | | AND 20-AMPERE RECEPTACLES SHALL BE LISTED | | | TAMPER-RESISTANT | | | RECEPTACLE | | | | | | 210.12 ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION. | | | (B) DWELLING UNITS. ALL 120-VOLT, SINGLE PHASE, 15- AND | | | 20-AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED | | | IN | | | DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, | | | RECREATION | | | ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS | | | SHALL BE | | | PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER, | | | COMBINATION-TYPE, INSTALLED TO PROVIDE PROTECTION OF | | | THE | | | BRANCH CIRCUIT. | | | | | | 250.94 BONDING FOR OTHER SYSTEMS. AN INTERSYSTEM | | | BONDING TERMINATION FOR CONNECTING INTERSYSTEM BONDING | | | AND GROUNDING CONDUCTORS REQUIRED FOR OTHER SYSTEMS | | | SHALL | | | BE PROVIDED EXTERNAL TO ENCLOSURES AT THE SERVICE | | | EQUIPMENT | | | AND AT THE DISCONNECTING MEANS FOR ANY ADDITIONAL | | | BUILDINGS | | | OR STRUCTURES. |
|