| Date |
Text |
| 2010-02-25 08:20:28 | BUILDING PLAN REVIEW |
| | PERMIT: 10020368 |
| | ADD: 1801 CENTREPARK 1ST FLOOR RESTROOMS |
| | CONT: ANDERSON MOORE |
| | TEL: (561)662-1819 |
| | |
| | FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| | W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | FEB. 25/2010 |
| | |
| | 1) SHEET A-1 DETAILS 1& 2 THE LADIES WATER CLOSETS WITH |
| | 6 WATER CLOSETSPLEASE REVIEW SECTION 11-4.22.4 THAT |
| | REQUIRES A AMBLATORY STALL. |
| | |
| | 2) SHEET A-1 DETAILS 1& 2 THE LADIES AMBLATORY STALL |
| | DOOR MUST HAVE A OUT SWING DOOR WITH 32 INCHES CLEAR |
| | SEE FIGURE 30(B). |
| | |
| | 3) SHEET A-2 THE WOMENS ELEVATIONS AT THE STALLS |
| | INDICATES WALL COVERING, NO NOTE ABOUT COMPLIANCE |
| | WITH:1210.2 WALLS. WALLS WITHIN 2 FEET (610 MM) OF |
| | URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, |
| | NONABSORBENT SURFACE, TO A HEIGHT OF 4 FEET (1219 MM) |
| | ABOVE THE FLOOR, AND EXCEPT FOR STRUCTURAL ELEMENTS, |
| | THE MATERIALS USED IN SUCH WALLS SHALL BE OF A TYPE |
| | THAT IS NOT ADVERSELY AFFECTED BY MOISTURE. |
| | |
| | 4) SHEET A-2 DETAILS FOR AN ACCESSIBLE LAV ARE PROVIDED |
| | (2'-5") , BUT IN THE ELEVATION VIEW THE SKIRT IN FRONT |
| | OF THE LAV IS NOT PROVIDED NOR THE MEASUREMENT FROM THE |
| | BOTTOM OF THE SKIRT TO THE FLOOR SURFACE. PLEASE REVIEW |
| | FIGURE 31 WITH A CLEAR HEIGHT. NOTE THE PLANS INDICATE |
| | THE FINISH COUNTER HEIGHT IS PROVIDED AT 2'-9", THE |
| | CLEAR HEIGHT FOR THE KNEES MUST STILL BE MAINTAINED!!! |
| | |
| | JIM WITMER C. B. O. |
| | COMMERCIAL COMBINATION PLAN REVIEW |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE |
| | CUSTOMER SERVICE SURVEY AT: |
| | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| | |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | |
| | |