Plan Review Notes
Plan Review Notes For Permit 10020362
Permit Number 10020362
Review Stop B
Sequence Number 2
Notes
Date Text
2010-03-17 13:05:58NOTE: CONTRACTOR OR REPRESENTATIVE NEEDS TO COME IN AND
 PULL OLD SHEETS AND INSERT NEW SHEETS BEFORE TTHE PLANS
 CAN BE STAMPED.
  
 BUILDING PLAN REVIEW
 PERMIT: 10020362
 ADD: 1701 OKEECHOBEE BLVD# 1727
 CONT: DEWHURST
 TEL: (561241-1540
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
 MARCH 17/ 2010
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). ALL MISSING OR
 APPROVALS NOT ACCEPTED WILL BE CONSIDERED A REVISION
 WITH ASSOCIATED FEES AND REVIEWS.
  
 MISSING PRODUCT APPROVALS WILL BE REQUIRED BEFORE
 FRAMING INSPECTION.
  
 1) ROOFTOP UNITS PLANS HAVEN'T PROVIDED ROOF TOP
 PRESSURES FOR ROOF TOP UNITS, MISSING WIND CRITERIA:
  
 1604.4 EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE
 OVERTURNING EFFECTS CAUSED BY LATERAL FORCES SPECIFIED
 IN THIS CHAPTER. SEE SECTION 1609 FOR WIND .
  
 1604.9 COUNTERACTING STRUCTURAL ACTIONS. STRUCTURAL
 MEMBERS, SYSTEMS, COMPONENTS AND CLADDING SHALL BE
 DESIGNED TO RESIST FORCES DUE TO WIND, WITH
 CONSIDERATION OF OVERTURNING, SLIDING, AND UPLIFT.
 CONTINUOUS LOAD PATHS SHALL BE PROVIDED FOR
 TRANSMITTING THESE FORCES TO THE FOUNDATION.
  
 1603.1.4 WIND DESIGN DATA.THE FOLLOWING INFORMATION
 RELATED TO WIND LOADS SHALL BE SHOWN, REGARDLESS OF
 WHETHER WIND LOADS GOVERN THE DESIGN OF THE
 LATERAL-FORCE-RESISTING SYSTEM OF THE BUILDING:
 1.1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR
 (KM/HR).
  
 1.2. WIND IMPORTANCE FACTOR, I W , AND BUILDING
 CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7
 AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7.
  
 1.3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS
 UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND
 DIRECTION SHALL BE INDICATED.
  
 1.4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF
 DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT.
  
 1.5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES
 IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR THE SELECTION
 OF EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT
 SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL.
  
 2) ANCHORING CALCULATIONS SUBMITTED FOR THE CARRIER
 MODELS DOES NOT HAVE MIAMI-DADE APPROVAL OR FLORIDA
 APPROVAL, COPIES OF REPORT ARE NOT ACCEPTABLE.
  
 PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS
 PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR
 PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE
 DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT.FL ADMIN
 CODE 61G15-23.002 ENGINEERS
  
 61G15-23.002(2) FL. ADMIN. CODE. A COVER SHEET OR INDEX
 SHEET FOR ENGINEERING SPECIFICATIONS MAY BE USED AND
 THAT SHEET MUST BE SIGNED IN RESPONSIBLE CHARGE OF THE
 PRODUCTION & PREPARATION OF EACH SECTION OF THE
 ENGINEERING SPECIFICATION WITH SUFFICIENT INFORMATION
 ON THE COVER SHEET OR INDEX.
  
 3) MIAMI-DADE NOA GREENHECK FAN MODEL FGI, FGR, &
 R-SERIES STEEL/ ALUMINUM ROOF FANS, PLEASE INDICATE IF
 FANS ARE TO BE STEEL OR ALUMINUM, PRESSURES FOR STEEL
 ARE +/- 130 PSF AND FOR ALULINUM FAN =/- 70. DESIGNER
 OF RECORD WILL NEED TO PROVIDE ROOF TOP PRESSURES IF
 PAREPETS WERE CONSIDERED AND ROOF ZONE LOCATIONS, ZONE
 1, 2 OR 3.
  
 4) CENTRIFUGAL ROOF EXHAUST FANS MODEL H-G AND H-GB NOA
 07-0503.07 SPEECS WERE SUBMITTED BUT NOT THE 63 PAGE
 NOA. PLEASE SUBMIT ONLY THE APPLICABLE SECTIONS OF THIS
 REPORT THAT PERTAIN TO THIS PRODUCT AND INSTALATION.
 PLEASE ALSO NOTE PRESSURES FOR THIS ROOF TOP UNIT.
  
 5) COMPLIED. ARCH ALUMINUM NOA06-0818.02 NOTE:
 NON-IMPACT GLAZING WILL REQUIRE SHUTTERS.
  
 6) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE
 REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
  