Plan Review Notes
Plan Review Notes For Permit 10020288
Permit Number 10020288
Review Stop B
Sequence Number 2
Notes
Date Text
2010-05-11 13:57:53BUILDING PROVISO:
 A SEPERATE ROOFING PERMIT WILL BE REQUIRED WITH
 ADDITIONAL REVIEW AND FEES. PRODUCT APPROVAL SUBMITTED
 REQUIRES RAS 117 CALCULATIONS TO BE PREPARED BY EITHER
 A ENGINEER, ARCHITECT OR A REGISTERED ROOFING
 CONSULTANT.
  
 ROOFING PRODUCT APPROVALS SUBMITTED:
 FL 479-R2
 CERTAINTEED CORPORATION- ROOFING
 MODIFIED BITUMEN ROOF SYSTEM
 PAGE 36 OF 39
 SBS MODIFIED
 DECK TYPE 1: WOOD, NON-INSULATED
 DECK DESCRIPTION: MIN 19/32" THICK PLYWOOD, NAILS
 SPACED 4" O.C. @ WOOD JOIST SPACED MAXIMUM 24" O. C.
 SYSTEM TYPE E(6)
 MAXIMUM DESIGN PRESSURE: -60 PSF (SEE GENERAL
 LIMITATION #7.
 LIMITATION #7 REQUIRES RAS 117 CALCULATIONS TO BE
 PREPARED BY EITHER A ENGINEER, ARCHITECT OR A
 REGISTERED ROOFING CONSULTANT.
  
 ROOF TILE
 FL8835-R1
 EAGLE ROOFING
 NOA: 07-1018.09 CAPISTRANO CONCRETE TILE
 PAGE 5 POLYFOAM POLY PRO LARGE 66.5/ SMALL 38.7