| Date |
Text |
| 2010-02-24 11:04:13 | BUILDING PLAN REVIEW |
| | PERMIT: 10020285 |
| | ADD: 1501 N AUSTRALIAN AVE |
| | CONT: AYA SOLUTIONS INC. |
| | TEL: (305)792-6720 |
| | |
| | FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| | W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | BUILDING APPROVED WITH EXCEPTION! |
| | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| | ASSESSMENT OF RE-INSPECTION FEE(S). |
| | |
| | 1) FL BLDG CODE- EXISTING BUILDING CODE SECTION 706.1- |
| | A BUILDING, FACILITY, OR ELEMENT THAT IS ALTERED SHALL |
| | COMPLY WITH CHAPTER 11 OF THE FLORIDA BUILDING CODE, |
| | BUILDING. |
| | |
| | 11-4.1.6 (2) ALTERATIONS TO AN AREA CONTAINING A |
| | PRIMARY FUNCTION AREA. |
| | ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF |
| | TRAVEL TO ALTERED AREAS SHALL BE DEEMED |
| | DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE |
| | COST EXCEEDS 20 PERCENT OF THE COST OF THE ALTERATION |
| | TO THE PRIMARY FUNCTION AREA. |
| | |
| | DUTY TO PROVIDE ACCESSIBLE FEATURES IN THE EVENT OF |
| | DISPROPORTIONALITY. |
| | |
| | (1) WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE |
| | PATH OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS |
| | DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION, |
| | THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE |
| | EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING |
| | DISPROPORTIONATE COSTS. |
| | (2)(A) IN CHOOSING WHICH ACCESSIBLE ELEMENTS TO |
| | PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE ELEMENTS |
| | THAT WILL PROVIDE THE GREATEST ACCESS, IN THE FOLLOWING |
| | ORDER: |
| | (I) AN ACCESSIBLE ENTRANCE; |
| | (II) AN ACCESSIBLE ROUTE TO THE ALTERED AREA: |
| | (III) AT LEAST ONE ACCESSIBLE RESTROOM FOR EACH SEX OR |
| | A SINGLE UNISEX RESTROOM: |
| | |
| | 1A) WITHIN BOTH THE WOMEN???S & MEN???S RESTROOMS THE |
| | PLANS APPEAR TO HAVE AN ACCESSIBLE STALL AND WHAT |
| | APPEARS TO BE A AMBULATORY ACCESSIBLE STALL WITH ONLY |
| | ONE GRAB BAR. BY CODE THESE STALLS DO NOT NEED TO MEET |
| | THIS REQUIREMENT. IF PROVIDED THEY MUST MEET THE |
| | REQUIREMENTS OF GRAB BARS ON BOTH SIDES, PLEASE SEE |
| | FIGURE 30 (B) FOR THE 36??? WIDE STALL AND THE REQUIRED |
| | DEPTH REQUIREMENTS FOR BOTH, FLOOR MOUNTED OR WALL |
| | MOUNTED FIXTURES. |
| | 1B) THE SECOND ISSUE WOULD BE THE DOORS WOULD BE |
| | REQUIRED TO BE 32??? CLEAR OPENINGS AND OUT SWING |
| | DOORS, SEE FIGURE 30 (B) ALTERNATE STALLS. |
| | |
| | JIM WITMER C. B. O. |
| | COMMERCIAL COMBINATION PLAN REVIEW |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |