2010-02-22 15:52:49****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007 WITH 2009 SUPPLEMENTS
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1-4. ADDRESSED.
  
 5. AS A SITE PLAN WAS NOT PROVIDED, IT IS NOT POSSIBLE
 TO CONFIRM EXPOSURE B DESIGN CRITERIA. PLEASE HAVE THE
 ENGINEER SEE FBC1609, THE SITE PLAN, AND AERIALS TO
 CONFIRM EXPOSURE B CATEGORY PRIOR TO RESUBMITTAL.
  
 2ND REVIEW, ENGINEER INCLUDED AN AERIAL WHICH WAS NOTED
 AS LOCATION 2490' FROM INTRACOASTAL. THIS INFORMATION
 WAS CLEAR IN THE FIRST REVIEW - IN THE FUTURE, IF IT IS
 NOT CLEAR TO THE ENGINEER WHY A COMMENT IS MADE, PLEASE
 CONTACT MEPRIOR TO RESUBMITTAL TO AVOID PROJECT DELAYS.
 THE PROPOSED LOCATION IS WITHIN 100' HORIZONTALLY OF OF
 OPEN AREA 600' IN THE UPWIND DIRECTION AND WIDTH
 GREATER THAN 150', SEE DEFINITION OF SURFACE ROUGHNESS
 C, ASCE7-05. BASED ON PROPOSED LOCATION, THIS IS
 EXPOSURE C. PLEASE REVISE SITE PLAN AND PROVIDE
 COMMENTARY IF NECESSARY IF ENGINEER FEELS THAT THIS IS
 EXPOSURE B AFTER REVIEW OF ASCE7-05 (WITH COMMENTARY)
 AND FBC1609.
  
 NEW COMMENT:
  
 6. PLEASE SEE WPB GIS AND PALM BEACH COUNTY PROPERTY
 APPRAISER. IT APPEARS THAT THE PARCEL ID IS INCORRECT,
 PROPOSED IMPROVEMENT IS ON THE LOT ENDING IN 0010.
 PLEASE REVISE OR CLARIFY.
  
  
  
  
  
  
  
  