Plan Review Notes
Plan Review Notes For Permit 10010525
Permit Number 10010525
Review Stop B
Sequence Number 2
Notes
Date Text
2010-08-26 08:35:49RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW
 SECOND CHECKLIST.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13
 FLORIDA STATUTE.
 NOTE: MAY BE RECORDED AT TIME OF PERMIT PICK UP.
  
 2- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD) TO VERIFY IF IMPACT FEES ARE
 DUE. BRING BACK STAMPED PLANS AND COPY OF PAID RECEIPT
 IF FEES ARE DUE. (REPEAT COMMENT. NOT ADDRESSED).
  
 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. SEC. 108.3 CITY AMENDMENTS TO FBC. OWES $2355.25.
 THIS INCLUDES THE BALANCE FOR THE PERMIT FEES AND FOR
 UPDATED VALUATION AND RADON FEES.
  
 4- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY
 DCA RULE 9B-72 FOR:
 A) ENTRY DOOR AS SHOWN ON PLANS/ELEVATIONS. (REPEAT
 COMMENT. NOT ADDRESSED).
  
 B) STORM SHUTTERS: NOA 04-0130.02 SUBMITTED EXPIRED ON
 02/08/09.
 ***NOTE: NEED TO PROVIDE ALSO A COMPLETE INSTALLATION
 SCHEDULE. SEE ATTACHED SAMPLE.
 AND, CLEARLY MARK ON SHUTTERS DRAWINGS SPECIFIC
 MOUNTING CONDITIONS AND SPECIFIC ANCHOR TYPE AND
 SPACING TO BE USED. (REPEAT COMMENT. NOT ADDRESSED).
  
 C) WINDOW MULLIONS AS SHOWN ON PLANS.
 ***NOTE: CLEARLY MARK ON MULLION PRODUCT APPROVAL
 SPECIFIC MULLION SIZE AND FASTENERS TO VERIFY
 COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. R301 OF
 2007 FLORIDA RESIDENTIAL CODE. (REPEAT COMMENT. NOT
 ADDRESSED).
  
 D) GARAGE DOOR AS SHOWN ON PLANS. (REPEAT COMMENT. NOT
 ADDRESSED).
  
 E) HURRICANE STRUCTURAL CONNECTORS SPECIFIED ON PLANS.
 ***NOTE: PROVIDE ONLY THE PRODUCT APPROVAL COVER PAGE
 AND PAGE SHOWING THE SPECIFIC CONNECTORS SPECIFIED ON
 PLANS. THIS APPLIES TO STRUCTURAL CONNECTORS ONLY.
 PROVIDE COMPLETE PRODUCT APPROVAL FOR ALL OTHERS.
 (REPEAT COMMENT. NOT ADDRESSED).
  
 F) METAL ROOF AS SHOWN ON PLANS. (REPEAT COMMENT. NOT
 ADDRESSED).
  
 G) METAL RIDGE VENTILATION AS SHOWN ON PLANS. (REPEAT
 COMMENT. NOT ADDRESSED).
  
 H) SINGLE HUNG WINDOWS. (NONE PROVIDED).
  
 I) WALL LOUVERS. NEW COMMENT. REVISED ELEVATIONS SHOW
 WALL LOUVERS ON GABLE ENDS.
  
 J) SLIDING GLASS DOORS AS SHOWN ON DOOR ELEVATIONS ON
 SHEET A-4. NOTE: CLARIFY TYPE OF DOOR TO BE USED. FLOOR
 PLAN SHOWS FRENCH DOORS, WHILE DOOR ELEVATION SHOWS
 SLIDING GLASS DOORS. REVISE AS REQUIRED.
  
 5- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC.
 (REPEAT COMMENT).
  
 6- A) NEED TO SPECIFY ON PLANS CARBON MONOXIDE ALARMS
 INSTALLED WITHING 10 FEET OF EACH ROOM USED FOR
 SLEEPING. SEC. R313.4.
 RESPONSE: REVISED ELECTRICAL PLAN SHOWS HEXAGONAL
 SYMBOL WITH THE LETTERS CO OUTSIDE THE BEDROOMS.
 CLARIFY IF THIS IS THE REQUIRED CARBON MONOXIDE ALARM.
 ELECTRICAL LEGEND DOESN'T SHOW THIS SYMBOL. REVISE AS
 REQUIRED.
  
 B) ELECTRICAL PLAN IS MISSING THE SMOKE ALARM OUTSIDE
 EACH SLEEPING AREA IN THE IMMEDIATE VICINITY AS
 REQUIRED BY SEC. R313.2(2).
  
 7- ENERGY CALCULATIONS: (REPEAT COMMENT. NOT
 ADDRESSED).
 A) PROVIDE CURRENT 2007 REVISED FORM. THE ONE SUBMITTED
 WAS FOR 2004 CODE.
 B) REVISE SQUARE FOOTAGE ON ITEM #6 TO MATCH PLANS.
  
 8- WINDOWS ON MASTER BEDROOM, BEDROOM #3 AND GUEST
 BEDROOM DON'T COMPLY WITH THE EGRESS REQUIREMENTS OF
 SEC. R310.1.1 AND R310.1.2 OF 2007 FLORIDA RESIDENTIAL
 CODE. REVISE SIZE AS REQUIRED.
 RESPONSE: PLEASE SPECIFY SIZE FROM PRODUCT APPROVAL
 SUBMITTED TO VERIFY COMPLIANCE WITH THE MIN. CLEAR
 OPENING HEIGHT AND TOTAL MIN. CLEAR OPENING.
  
 9- PROVIDE ROOF CROSS VENTILATION AS REQUIRED BY SEC.
 R806.1. RIDGE VENTILATION AS SHOWN ON ELEVATIONS AND
 ROOF PLAN DOESN'T PROVIDE CROSS VENTILATION. NEED TO
 PROVIDE VENTILATION ON EAVES OR GABLE ENDS TO OBTAIN
 CROSS VENTILATION.
 ALSO, PROVIDE COMPLETE DETAILS AND SPECIFICATIONS
 SHOWING HOW TO BUILT THE RIDGE VENTILATION ON A METAL
 ROOF AS SPECIFIED ON PLANS.
  
 RESPONSE: CLARIFY HOW COMPLYING WITH THE ROOF CROSS
 VENTILATION REQUIREMENTS. EXTERIOR ELEVATIONS CALL FOR
 CONTINUOUS RIDGE VENT. HOW IS THIS ACHIEVED. ALSO,
 SPECIFY VENT SIZE AND SPACING ON DRAWING #5 OF SHEET
 S-2.
  
 10- SPECIFY ALL ROOF LIVE AND DEAD LOADS INCLUDING THE
 ATTIC LIVE LOADS AS REQUIRED BY TABLE R301.5. CLEARLY
 IDENTIFY TRUSS TOP CHORD LIVE AND DEAD LOADS AND TRUSS
 BOTTOM CHORD LIVE AND DEAD LOADS. (REPEAT COMMENT. NOT
 ADDRESSED).
  
 11- SHEET A0:
 A- REVISE CONSTRUCTION TYPE SHOWN ON PROJECT DATA
 INFORMATION. THIS BUILDING IS NOT CONSTRUCTION TYPE IV.
 SEE SEC. 602 OF 2007 FBC FOR CORRECT TYPE OF
 CONSTRUCTION.
  
 RESPONSE: CORRECT CONSTRUCTION TYPE IS VB. REVISE AS
 REQUIRED.
  
 B) WALL LEGEND NOTES: (REPEAT COMMENT).
 *REVISE INSULATION R VALUE SHOWN ON THE EXTERIOR WALLS.
 COORDINATE WITH THE ENERGY CALCULATIONS.
 **COORDINATE NOTES FOR HARDIPLANK INSTALLATION.
 INFORMATION SHOWN ON NEW EXTERIOR WALL NOTE DOESN'T
 MATCH HARDIPLANK NOTES SHOWN BELOW. SEE COMMENTS ON
 PLANS.
  
 12- SHEET A-1:
 A) REVISE THE DESIGN CRITERIA. ACCORDING TO SEC.
 R301.2.1.4.3 OF 2009 REVISIONS TO THE 2007 FLORIDA
 RESIDENTIAL CODE THIS BUILDING IS LOCATED ON EXPOSURE
 "C". REVISE EXPOSURE AND THE DESIGN PRESSURES
 ACCORDINGLY.
 ALSO, REVISE CODE SECTION. NEED TO USE FBC 2007 NOT
 2004.
  
 RESPONSE: ONLY THE BUILDING EXPOSURE WAS REVISED. THE
 DESIGN PRESSURES AND THE CORRECT BUILDING CODE WAS NOT
 REVISED.
  
 B) REVISE ENERGY CALCULATIONS REQUIREMENTS INFORMATION
 TO MATCH ENERGY CALCULATIONS SUBMITTED. COORDINATE WITH
 ITEM #7 ABOVE. (REPEAT COMMENT).
  
 C) REVISE WALL LEGEND INFORMATION. SEE ITEM #11(B)
 ABOVE.
  
 D) SPECIFY SAFETY GLAZING FOR WINDOWS LOCATED ON BOTH
 BATHROOMS. SEC. R308.4(5). AND FOR WINDOW IN THE GREAT
 ROOM NEXT TO THE GARAGE SWING DOOR. SEC. R308.4((6).
 (REPEAT COMMENT. NOT ADDRESSED. AND NOT CLEAR IF USING
 IMPACT WINDOWS OR NON-IMPACT WINDOWS. WIND DESIGN
 CRITERIA ON SHEET A-1 SPECIFIES IMPACT GLASS, BUT
 WINDOW SCHEDULE DOESN'T SPECIFY IMPACT. AND, WINDOW
 PRODUCT APPROVAL WAS NOT SUBMITTED)
  
 E) ENTRY DOOR DOESN'T MATCH DOOR SHOWN ON FRONT
 ELEVATION AND DOOR SPECIFIED ON DOOR SCHEDULE. REVISE
 AS REQUIRED TO MATCH. SEE ITEM #4A ABOVE. (REPEAT
 COMMENT. NOT ADDRESSED).
  
 13- SHEET A-2:
 A)REVISE ELEVATION NOTES TO MATCH PRODUCT APPROVALS
 SUBMITTED. DOOR PRODUCT APPROVAL SUBMITTED HAVE NOT
 IMPACT GLAZING. (REPEAT COMMENT).
  
 B) ELEVATIONS SHOW CONTINUOUS RIDGE VENT. COORDINATE
 WITH ITEM #4(G) ABOVE. (REPEAT COMMENT). PROVIDE
 COMPLETE DETAILS AND SPECIFICATIONS FOR CONTINUOUS
 RIDGE VENT.
  
 14- SHEET A-4:
 A) REVISE WINDOW SCHEDULE: WINDOW TYPE IS CASEMENT OR
 SINGLE HUNG. IMPACT OR NON IMPACT (COORDINATE WITH
 PRODUCT APPROVAL SUBMITTED. REVISE FOOTNOTE. NEED TO
 SPECIFY 2007 FBC NOT 2004. (REPEAT COMMENT. NOT
 ADDRESSED).
  
 B) REVISE WINDOW GENERAL NOTE #1. STOREFRONT SYSTEM
 DOESN'T APPLY TO THIS PROJECT. (REPEAT COMMENT. NOT
 ADDRESSED).
  
 C) REVISE DOOR ELEVATION TYPE F. IS THIS A FRENCH DOOR
 OR SLIDING GLASS DOORS. SEE PLANS. ALSO, WHAT'S "DOUBLE
 SLIDING GLASS"?. (REPEAT COMMENT).
  
 15- SHEET S-1:
 A) PROVIDE TRUSS ANCHOR SCHEDULE TO VERIFY COMPLIANCE
 WITH SEC. R301. (REPEAT COMMENT). SIMPSON H6 CONNECTOR
 SPECIFIED ON DETAIL 5 OF SHEET S-2 DOESN'T PROVIDE
 ADEQUATE CONNECTION TO RESIST THE LATERAL LOADS. SEE
 SIMPSON CATALOG AND REVISE AS REQUIRED.
  
 16- SHEET S-2:
 A) PROVIDE ONLY THE DETAILS THAT APPLY TO THIS PROJECT.
 KEY EACH DETAIL ON THIS SHEET ON FOUNDATION AND ROOF
 FRAMING PLAN TO VERIFY PROPER INSTALLATION. (REPEAT
 COMMENT. NOT ADDRESSED).
  
 B) WALL FRAMING DETAIL IS INCORRECT. IS MISSING THE
 OPENING HEADER. CLARIFY WHY THERE IS ONLY ONE 2X STUD
 SHOWN FOR THE WINDOW SILL. REVISE NUMBER OF STUDS
 REQUIRED AT JAMBS. PROVIDE COMPLETE FRAMING DETAIL FOR
 DOUBLE FRENCH DOORS. PROVIDE COMPLETE FRAMING DETAILS
 FOR INSTALLATION OF DOUBLE WINDOWS AS SHOWN ON PLANS.
 HOW ARE THE OPENINGS FRAMINGS REINFORCED TO RECEIVE THE
 STORM SHUTTERS? (REPEAT COMMENT. NOT ADDRESSED).
  
 C) SECTION 5: REVISE ROOF SHEATHING SPECIFICATIONS TO
 MATCH SPECIFICATIONS SHOWN ON SHEET A-3. SIMPSON H6
 CONNECTOR IS NOT A TRUSS TO WALL CONNECTOR AND IT
 DOESN'T PROVIDE RESISTANCE FOR LATERAL LOADS. SEE
 SIMPSON CATALOG AND REVISE AS REQUIRED. SPECIFY HOW ARE
 THE 2X6 STUDS ATTACHED AT TOP AND BOTTOM. CLARIFY WHY
 IS THERE A CONCRETE CURB SHOWN ON THE SECTION. (REPEAT
 COMMENT. NOT ADDRESSED).
  
 D) SECTION 6: FOOTING DOESN'T MATCH FOUNDATION PLAN.
 REVISE COLUMN BASE CONNECTOR (IT CAN'T BE EMBEDDED IN
 THE CONCRETE AS SHOWN ON THE DETAIL). REVISE COLUMN CAP
 CONNECTOR. SEE SIZE OF BEAM AND SIMPSON CATALOG AND
 REVISE AS REQUIRED. SPECIFY FASTENERS USED FOR THE
 HORIZONTAL BRACING. PROVIDE COMPLETE SPECIFICATIONS FOR
 GABLE END OUTLOOKERS INCLUDING FASTENERS. PROVIDE
 SPECIFICATIONS AND DETAILS FOR CONNECTION OF GABLE END
 TRUSS TO THE BEAM BELOW. (REPEAT COMMENT. NOT
 ADDRESSED).
  
 17- SHEET S-3:
 A) PROVIDE ONLY THE DETAILS THAT APPLY TO THIS PROJECT
 AND KEY THEM TO THE FOUNDATION AND ROOF FRAMING PLANS.
 (REPEAT COMMENT. NOT ADDRESSED).
  
 B) DESIGN LOADS: SPECIFY ALL LOADS INCLUDING THE ATTIC
 LIVE LOAD AS REQUIRED BY TABLE R301.5. REVISE EXPOSURE
 TO BE "C". (REPEAT COMMENT. NOT ADDRESSED). ALSO REVISE
 THE DESIGN PRESSURES THAT CORRESPOND TO EXPOSURE "C".
  
 C) REVISE PLYWOOD SHEATHING NOTES TO MATCH
 SPECIFICATIONS SHOWN ON SHEET A-3. (REPEAT COMMENT. NOT
 ADDRESSED).
  
 ***NOTE:
 PLEASE PROVIDE WRITTEN RESPONSE TO EACH ITEM TO
 EXPEDITE REVIEW PROCESS.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712