| Date |
Text |
| 2010-02-01 10:24:02 | DENIED |
| | REFERENCE: |
| | FBC-2007 PLUMBING |
| | FBC-2007 RESIDENTIAL |
| | FBC-2007 EXISTING BUILDING |
| | FBC-2007 CHAPTER 1 |
| | |
| | 1. SHT A2-06 MORE INFORMATION REQUIRED. SECTION |
| | 106.1.1. SUBMIT THE FOLLOWING: |
| | |
| | A. INDICATE THE TOTAL SQUARE FOOTAGE BEING DRAINED BY |
| | THE EXISTING ROOF DRAIN. SHOW TOTAL SQUARE FOOTAGE OF |
| | EXISTING ROOF SECTION WITH THE ROOF DRAIN, THE SQUARE |
| | FOOTAGE OF THE NEW ROOF DRAINING ON TO THE ROOF, ONE |
| | HALF THE ADDITIONAL SQUARE FOOTAGE OF THE VERTICAL |
| | WALLS FOR THE NEW ROOF, THE SQUARE FOOT AREA OF THE HIP |
| | ROOF THAT DRAINS ONTO THE ROOF & THE SQUARE FOOTAGE OF |
| | THE CHANGE IN LEVEL INDICATED (PLEASE CLARIFY). |
| | SECTIONS 1101.2, 1106.4, 1107.1, 1107.2 & 1107.3 AS |
| | WELL AS TABLES 1106.2, 1106.3 & 1106.2. |
| | |
| | B. SUBMIT A DETAIL FOR THE SCUPPER ON THE NEW ROOF. |
| | INDICATE HEIGHT, WIDTH, LENGTH. TABLE 1106.7. |
| | |
| | C. INDICATE THE SIZE OF THE EXISTING ROOF DRAIN AS WELL |
| | AS THE SIZE OF THE VERTICAL & HORIZONTAL CONDUCTOR & |
| | LEADER. TABLES 1106.2, 1106.3 & 1106.7. |
| | |
| | D. INDICATE THE SIZE OF THE EXISTING OVERFLOW SCUPPERS |
| | SERVING THE EXISTING ROOF WITH THE ROOF DRAIN. TABLE |
| | 1106.1. |
| | |
| | E. FOR THE NEW ROOF, A SEPARATE SECONDARY ROOF DRAIN IS |
| | REQUIRED PER SECTIONS 1107.1 & 1107.2. PLEASE SUBMIT A |
| | DETAIL AND SHOW THE LOCATION OF THE SECONDARY ROOF |
| | DRAIN. ALSO SEE SECTION R903.4.1. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, |
| | WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE |
| | ALL VOID SHEETS FROM ALL PLANS AND PLACE |
| | ONE SET OF THEM LOOSELY ON TOP OF THE |
| | COLLATED PLANS TO BE REVIEWED. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 805-6721 |
| | FAX (561) 805-6731 |
| | E-MAIL [email protected] |
| | |