| Date |
Text |
| 2010-01-26 18:51:50 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2007 |
| | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING |
| | CODE |
| | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007 |
| | FAC FLORIDA ADMINISTRATIVE CODE |
| | FS FLORIDA STATUTE |
| | |
| | 1. TENANT SEPARATION WALL IS TO MAINTAIN 1 HOUR RATING, |
| | FBC 708.1(7), 708.3, 708.4. WALL DETAIL W3 IS SPECIFIED |
| | FOR DOOR INFILL. PLEASE REVISE TO SPECIFY A 1 HOUR WALL |
| | INFILL DETAIL. |
| | |
| | 2. PROVIDE OCCUPANT LOAD FOR EACH TENANT SPACE, FBC |
| | 1004.1. |
| | |
| | 3. DOOR 10 (LOBBY 200) SWINGS AGAINST THE PATH OF EXIT |
| | TRAVEL, FBC1008.1.2. IT IS NOT CLEAR HOW MANY OCCUPANTS |
| | THIS EXIT SERVES, BUT PLEASE NOTE THAT THIS IS A |
| | PRIMARY EXIT AS NOTED ON THE PLAN. |
| | |
| | 4. ABOVE THE TEXT "LIFE SAFETY PLAN" THERE IS A DASHED |
| | LINE (INVERTED "U"); PLEASE LABEL AS IT IS UNCLEAR WHAT |
| | THIS GRAPHIC REPRESENTS. |
| | |
| | 5. DOOR 11 AT VESTIBULE 207, SHOW 18??? CLEARANCE ON |
| | PULL SIDE PER FBC FIGURE 11-25. |
| | |
| | 6. PROVISO ITEM - UL DETAILS (HW AND CL, SEE SHEET |
| | A3.1) TO BE PROVIDED AT INSPECTION. |
| | |
| | 7. BATHROOMS ARE A COMMON AREA (TENANCY IN COMMON) AND |
| | REQUIRE TENANT SEPARATION, FBC 708.1(7), PENETRATIONS |
| | TO COMPLY WITH FBC712. |
| | |
| | 8. DETAIL 04 A3.1, BREAK ROOM SINK TO BE ACCESSIBLE, |
| | FBC 11-4.24. |
| | |
| | |