2009-12-22 15:45:06****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
  
 1. PROVIDE BUILDING HEIGHT. DESIGN PRESSURES FOR
 BUILDINGS OVER 60FEET ARE REQUIRED TO BE DESIGNED USING
 ASCE7, FBC1609.1.1. DOCUMENTS PREPARED BY AN ENGINEER
 AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED
 ORIGINALS FAC61G15-23.002.
  
 2. FOR THE SLIDING GLASS DOORS, CIRCLE WHICH GLASS
 OPTION/DESIGN PRESSURE APPLIES TO THE PROPOSED DOOR,
 SEE PAGES 2 AND 3 OF THE PRODUCT APPROVAL.
  
 3. IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R
 301.2.1.2. PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS
 ARE USED, COMPLETE THE SAMPLE INSTALLATION SCHEDULE
 (AVAILABLE IN THE LOBBY AND AT HTTP://WWW.CITYOFWPB.COM
 /CONSTRUCTION/PDF/SCHEDULE_FOR_INSTALLATION.PDF).
 GLAZED OPENINGS LOCATED MORE THAN 30' ABOVE GRADE SHALL
 MEET THE PROVISIONS OF THE SMALL MISSILE TEST.
  
 I WAS UNABLE TO LOCATE A PERMIT FOR IMPACT PROTECTION
 FOR THIS UNIT. A PERMIT WAS ISSUED FOR FOUR ACCORDION
 SHUTTERS, BUT THAT PERMIT WAS NEVER FINALED. IF THE
 PROPOSED SLIDING GLASS DOORS HAVE FBC COMPLIANT
 EXISTING IMPACT PROTECTION, PLEASE PROVIDE EVIDENCE OF
 IMPACT PROTECTION FOR THESE OPENINGS (PERMIT NUMBER
 WHICH HAS A FINAL INSPECTION).
  
 4. PROVIDE A FLOOR PLAN WHICH SHOWS THE LOCATION OF THE
 PROPOSED INTERIOR IMPROVEMENT. PROVIDE A WALL FRAMING
 DETAIL FOR THE NEW OPENING.
  
  