Plan Review Notes
Plan Review Notes For Permit 09120051
Permit Number 09120051
Review Stop B
Sequence Number 2
Notes
Date Text
2010-01-21 13:06:00****PROVISOS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. CURRENT FLORIDA STATE OR LOCAL PRODUCT APPROVAL (OR
 MIAMIDADE NOA) REQUIRED FOR THE DOOR, FAC9B-72. PROVIDE
 AT INSPECTION.
  
 2. SUBJECT TO INSPECTOR'S DISCRETION, THE FOLLOWING MAY
 BE REQUIRED (EITHER SUBMITTED IN THE FIELD OR SUBMITTED
 AS A REVISION FOR REVIEW):
  
 A STRUCTURAL DETAIL FOR THE NEW DOOR OPENING
  
 3. ADVISORY ONLY - THE PHOTOGRAPH PROVIDED STATES THAT
 FIVE FASTENERS PER JAMB WERE INSTALLED. WINDOWS ARE TO
 BE INSTALLED IN ACCORDANCE WITH THE PRODUCT APPROVAL.
 SEE DRAWING 1 OF THE CURRENT MIAMIDADE NOA (THE ONE
 PROVIDED IS EXPIRED), AN 18X48 WINDOW REQUIRES 8
 ANCHORS AT EACH JAM INCLUDING 2 AT THE MEETING RAIL.
 PRIOR TO INSPECTION, TO AVOID REINSPECTION FEES, PLEASE
 CONFIRM THAT WINDOWS AND DOORS ARE INSTALLED IN
 ACCORDANCE WITH THE CURRENT PRODUCT APPROVAL.
  
  
  