2010-01-05 11:59:44BUILDING PLAN REVIEW
 PERMIT: 09110301
 ADD: 300 NORTHPOINT PARKWAY
 CONT: ITASCA
 TEL: (954)714-6998
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2ND REVIEW
 ACTION: REVIEWED
 JAN. 05/2010
  
 BUILDING PROVISO:
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S).
  
 1) SHEET A100 DOOR# 6 IS A NEW DOOR AND FRAME REQUIRING
 PRODUCT APPROVALS ( FL ADMINISTRATIVE CODE RULE
 9B-72.31(A). CONTRACTOR TO PROVIDE BEFORE FRAMING
 INSPECTION.
  
 2) SHEET A130 TABLE 1019.2, THE TRAVEL DISTANCE FOR THE
 S-2 WAREHOUSE WILL REQUIRE THE 2ND EXIT. THE DOOR
 BETWEEN THE PHARMACY SHIPPING AND WAREHOUSE IS THE 2ND
 REQUIRED MEANS OF EGRESS FROM THE WAREHOUSE. 1014.2
 ALLOWS FOR EGRESS THROUGH INTERVENING SPACES AS LONG AS
 THE DOORS ARE NOT LOCKED.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]