| Plan Review Notes For Permit 09110285 |
| Permit Number |
09110285 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2009-12-01 17:53:07 | DENIED | | | REFERENCE: | | | FBC-2007 PLUMBING | | | FBC-2007 CHAPTER 1 | | | | | | 1. A SANITARY ISOMETRIC RISER DIAGRAM IS REQUIRED. | | | SECTION 106.3.5.1.3(4)(6)(13). PLEASE SHOW ALL PIPE | | | SIZES, TRAPS, VENTS ETC. SECTIONS 701.1, 901.1 & | | | 1001.1. | | | | | | 2. A WATER ISOMETRIC RISER DIAGRAM IS REQUIRED. SECTION | | | 106.3.5.1.3(3)(10(13). PLEASE SHOW ALL PIPE SIZES, | | | VALVES AND (WHERE REQD BY SECTION 604.9) WATER HAMMER | | | ARRESTORS. SECTION 601.1. | | | | | | 3. SHT G1.01 SCOPE OF WORK INDICATES "REMOVE & REPLACE | | | KITCHEN CABINETS & APPLIANCES" WILL ANY OF THE | | | APPLIANCES BE NEW APPLIANCES? IF YES WILL THERE BE ANY | | | NEW GAS APPLIANCES? PLEASE CLARIFY. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|