2009-11-20 08:57:06BUILDING PLAN REVIEW
 PERMIT: 09110285
 ADD: 4812 S DIXIE HWY
 CONT: ALL CRETE CONSTRUCTION
 TEL: (561)704-5047
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 NOV19-20/ 2009
 1ST REVIEW
 ACTION: DENIED
  
 1) BOTH THE PERMIT APPLICATION AAND PLANS INDICATE THE
 PARKING LOT IS TO BE RE-STRIPED. G1.01 THE SITE PLAN
 DOES NOT PROVIDE DIMENSIONS TO THE STANDARD PARKING
 SPACES NOR THE ACCESSIBLE PARKING SPACE OR THE ACCESS
 AISLE AND ACCESSIBLE ROUTE, PLEASE PROVIDE DETAIL IN
 ACCORDANCE WITH SECTION 11-46.2, (1), 11-4.6.3,
 11-4.6.4 & 11-4.3.2(1). ALSO SEE FIGURE 9(A).
  
 2) PLANS (G1.01) ALSO INDICATE IN SCOPE OF WORK NOTE# 2
 THE REMOVAL AND REPLACEMENT OF KITCHEN CABINETS AND
 APPLIANCES, PLEASE PROVIDE UPDATE AS TO THE LOCATION OF
 KITCHEN, NOT SHOWN ON PLAN. IF THE TERM KITCHEN REFERS
 TO THE EXISTING BAR THEN PROVIDE COMPLIANCE WITH
 SECTION 11-5.2 .
  
 3A) SHEET G1.01 INDICATES THE SCOPE OF WORK LIMITED TO
 6 ITEMS, WHERE AS WHEN SPEAKING WITH CHIEF ELECTRICAL
 INSPECTOR JAKE LEAHY THE INTERIOR OF THE BUILDING THE
 SCOPE OF WORK HAS EXCEEDED THE DESCRIPTION OF WORK,
 PLEASE PROVIDE EXPLANATION. 106.1.2 ADDITIONAL
 INFORMATION REQUIRED.
  
 3B) THE CONTRACT VALUE OF WORK LISTED ON THE PERMIT
 APPLICATION IS LOW,, PLUS THE DECREPANCY OF WORK.
 PLEASE UPDATE THE VALUE TO THE TRUE REFLECTION OF WORK
 AND ASSOCIATED FEES TO BE REFLECTED WITHIN THE PERMIT.
 W P B ADMINISTRTIVE CODE 108.2 SCHEDULE OF PERMIT FEES.
 ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS, MECHANICAL,
 AND PLUMBING SYSTEMS OR ALTERATIONS REQUIRING A PERMIT,
 A FEE FOR EACH PERMIT SHALL BE PAID AS REQUIRED, IN
 ACCORDANCE WITH THE SCHEDULE ESTABLISHED BY THE
 APPLICABLE GOVERNING AUTHORITY.
  
 108.3* BUILDING PERMIT VALUATION.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 4) THE PLANS SHEET A1.01 & A1.02 BOTH INDICATE ON THE
 SOUTH ELEVATION NEW GLAZED DOOR AND WINDOW OPENINGS:
 4A) SHEET A1.02 DOES INDICATE TO GROUT CELLS BELOW THE
 WINDOW @ 48 INCHES ON CENTER BUT NO MENTION AS TO WHAT
 TO DO WITH THE WINDOW SILL? 1604.9 CONTINOUS LOAD
 PATHS, TO PREVENT OVERTURNING, SLIDING AND UPLIFT.
  
 4B) THE PRODUCT APPROVALS SUBMITTED DO NOT HAVE LARGE
 MISSILE TESTING REQUIRING EITHER STORM SHUTTERS OR
 STORM PANELS PLEASE PROVIDE PRODUCT APPROVALS.
 1609.1.4 PROTECTION OF OPENINGS IN WIND-BORNE DEBRIS
 REGIONS, EXTERIOR GLAZING THAT RECEIVES POSITIVE
 PRESSURE IN THE LOWER 60 FEET (18.3 M) IN BUILDINGS
 SHALL BE ASSUMED TO BE OPENINGS AND THE BALANCE OF
 GLAZED OPENINGS IN THE REST OF THE BUILDING SHALL BE
 ASSUMED TO BE ZERO UNLESS SUCH GLAZING THAT RECEIVES
 POSITIVE PRESSURE IS IMPACT RESISTANT OR PROTECTED WITH
 AN IMPACT RESISTANT COVERING MEETING THE REQUIREMENTS
 OF SSTD 12, ASTM E 1886 AND ASTM E 1996, OR MIAMI-DADE
 TAS 201, 202 AND 203 REFERENCED THEREIN AS FOLLOWS: 1.
 GLAZED OPENINGS LOCATED WITHIN 30 FEET (9.1 M) OF GRADE
 SHALL MEET THE REQUIREMENTS OF THE LARGE MISSILE TEST.
 2. GLAZED OPENINGS LOCATED MORE THAN 30 FEET (9.1 M)
 ABOVE GRADE SHALL MEET THE PROVISIONS OF THE SMALL
 MISSILE TEST.
  
 4C) PROVIDE STORM PANEL INFORMATION WITH INSTALLATION
 SCHEDULE AND KEY PLAN WITH SPECIFIC ANCHORS AND
 MOUNTING TO BE USED FOR ALL NON-IMPACT GLAZING. FBC
 1609.1.4.
  
 FL BLD CODE 2004 SECTION 106.3.3, 1609.1.4, 1714.5.1 &
 EXIST BUILD CODE 507.3. PROCEDURES: 1(B) A COMPLETE
 INSTALLATION SCHEDULE SUMMARIZING & IDENTIFYING OPENING
 SIZES, STORY HEIGHTS, UNIT MARK NUMBERS, UNIT
 SPANS/WIDTHS, UNIT STORM BAR REINFORCING REQUIREMENTS,
 WALL PRESSURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION TO FACILITATE
 PLAN REVIEW AND PERMIT ISSUANCE. PLEASE SEE ATTACHED
 SAMPLE.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES
 DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER
 NOTICE.
  
 OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM
 - 5:00 PM.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved