| Date |
Text |
| 2009-12-08 11:07:25 | BUILDING PLAN REVIEW |
| | PERMIT: 09110277 |
| | ADD: 534 DATURA ST |
| | CONT: ATLANTIC BAY PARTNERS INC |
| | TEL: (954)600-4646 |
| | |
| | FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| | W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | DECEMBER 08/ 2009 |
| | |
| | 1) A CLARIFICATION OF THE SCOPE OF WORK TO BE |
| | ACCOMPLISHED UNDER THIS PERMIT NEEDS TO BE ADDRESSED. |
| | THE PERMIT APPLICATION DESCRIPTION PROJECT IN DETAIL |
| | INDICATES COMMON AREAS ON THE FIRST FLOOR WHERE AS THE |
| | COVERSHEET OF THE PLANS UNDER PROJECT DESCRIPTION |
| | INDICATES COMMON AREAS FOR THE FIRST AND SECOND FLOOR. |
| | PLANS ONLY INDICATE THE FIRST FLOOR. 106.1.2 |
| | ADDITIONAL INFORMATION IS REQUIRED. |
| | |
| | 2) ADDITIONAL INFORMATION IS REQUIRED TO BE ABLE TO |
| | COMPLETE THIS REVIEW THOROUGHLY. |
| | |
| | 2A) MINIMUM BUILDING TYPE PER TABLE 503 & TABLE 601. |
| | |
| | 2B) IS THE BUILDING FULLY FIRE SPRINKLERED? |
| | |
| | 2C) THE BUILDING IS A MIXED USE OCCUPANCY , IS THE |
| | DESIGN CRITERIA SEPARATED USE 508.3.1.3 FOR OCCUPANCIES |
| | OR NON-SEPARATED OCCUPANCIES 508.3.2? |
| | |
| | 2D) PLANS WILL NEED TO INDICATE ONCE THE SPRINKLER |
| | ISSUE IS KNOWN, WALL AND CEILING FINISHES PER SECTION |
| | 803.1 AND TABLE 803.5 FOR OCCUPANCIES, CORRIDORS ,ETC. |
| | |
| | 2E) OCCUPANCY LOADS PER TABLE 1004.1.1. |
| | |
| | 2F) 2007 W 2009 SUPPLEMENTS EXISTING BUILDING CODE- |
| | SECTION 401.4 A DESIGN PROFESSIONAL OR OWNER MUST ELECT |
| | ONE OR MORE OR A COMBINATION OF LEVELS OF ALTERATION |
| | PURSUANT TO SECTIONS 403,404 AND 405 OF THIS CODE. |
| | |
| | 2G) FLOOR CEILING ASSEMBLIES WILL NEED TO INDICATE |
| | COMPLIANCE WITH TABLE 601 AND 803.9.1.2 |
| | FIRE-RESISTANCE-RATED CONSTRUCTION. ACOUSTICAL CEILING |
| | SYSTEMS THAT ARE PART OF FIRE-RESISTANCE-RATED |
| | CONSTRUCTION SHALL BE INSTALLED IN THE SAME MANNER USED |
| | IN THE ASSEMBLY TESTED AND SHALL COMPLY WITH THE |
| | PROVISIONS OF CHAPTER 7. |
| | |
| | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. |
| | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES |
| | DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER |
| | NOTICE. |
| | |
| | OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM |
| | - 5:00 PM. |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE |
| | CUSTOMER SERVICE SURVEY AT: |
| | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| | |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |
| | |
| | |
| | |
| | |