| Date |
Text |
| 2009-12-08 09:17:30 | BUILDING PLAN REVIEW |
| | PERMIT: 09110267 |
| | ADD: 11125 CLARE AVE |
| | CONT: BUTLER CONSTRUCTION |
| | TEL: (561)832-9700 |
| | |
| | FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| | W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | DECEMBER 08/ 2009 |
| | |
| | 1) MISSING WIND DESIGN, 1609.6.2 WIND DESIGN PROCEDURES |
| | 1.1) THE BASIC WIND SPEED, V, SHALL BE DETERMINED IN |
| | ACCORDANCE WITH SECTION 1609.3. THE WIND SHALL BE |
| | ASSUMED TO COME FROM ANY HORIZONTAL DIRECTION. |
| | |
| | 1.2) AN IMPORTANCE FACTOR, IW, SHALL BE DETERMINED IN |
| | ACCORDANCE WITH SECTION1609.5. |
| | |
| | 1.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN |
| | ACCORDANCE WITH 1609.4. |
| | |
| | 1.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * |
| | SHALL BE DETERMINED FROM TABLE 1609.6.2.1(4) |
| | PROVIDE POSITIVE & NEGATIVE PRESSURES FOR ROOF ZONES |
| | 1,2 & 3. |
| | |
| | 2) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, |
| | PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING |
| | REPORTS ARE AS FOLLOWS: |
| | 2.1) STANDING SEAM METAL ROOF |
| | |
| | 3) PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION |
| | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE |
| | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE |
| | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. |
| | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT |
| | IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT |
| | HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR |
| | LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE |
| | 9B-72. SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 4) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE |
| | REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND |
| | APPROVED IN WRITTING BY THE DESIGNER OF RECORD PRIOR TO |
| | SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | |
| | 5) PLEASE REVIEW ROOF SHEATHING NAILING PATTERNS IN THE |
| | 2007 FBC (DOUBLE LINED IN MARGIN, CODE CHANGE) |
| | SECTIOIN, TABLE 2304.9.1(31) |
| | 6 INCH O.C. EDGES AND INTERMEDIATE, 4 INCH O.C. AT |
| | COMPONENT AND CLADDING EDGE STRIP #3 [REFER TO FIGURE |
| | 6-3 OF ASCE 7] |
| | |
| | 7) CANOPY PLAN INDICATES A 8"X16" BEAM: |
| | |
| | 7.1) THE MINIMUM DESIGN MIX FOR CONCRETE BEAMS IS NOT |
| | PROVIDED PER SECTION 1905.1.1. |
| | |
| | 7.2) PLANS DO NOT INDICATE SPACING OF STIRRUPS PER: |
| | 907.13 REQUIREMENTS FOR STRUCTURAL INTEGRITY. THE |
| | DETAILING OF REINFORCEMENT AND CONNECTIONS BETWEEN |
| | CONCRETE MEMBERS SHALL COMPLY WITH THE PROVISIONS OF |
| | ACI 318, SECTION 7.13, TO IMPROVE STRUCTURAL INTEGRITY. |
| | |
| | ACI 530 BEAMS 7.5.3.1 SHEAR REINFORCEMENT SHALL BE |
| | PARALLEL TO THE DIRECTION OF APPLIED SHEAR FORCE. |
| | SPACING OF SHEAR REINFORCEMENT SHALL NOT EXCEED THE |
| | LESSER OF D/2 OR 48 INCHES. |
| | |
| | 8) THE FOUNDATION PLAN INDICATES A 24 INCH BY 24 INCH |
| | BY 8 INCH COLUMN BUT PLANS INDICATE A 24 INCH BY 8 |
| | INCH, COLUMN LOCATION FURTHEST TO THE RIGHT. THERE |
| | APPEARS TO BE A DISCREPANCY, POSSIBLY A TYPE-O. 106.1.2 |
| | ADDITIONAL INFORMATION REQUIRED. |
| | |
| | INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. |
| | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES |
| | DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER |
| | NOTICE. |
| | |
| | OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM |
| | - 5:00 PM. |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE |
| | CUSTOMER SERVICE SURVEY AT: |
| | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| | |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |
| | |
| | |
| | |
| | |