| Date |
Text |
| 2009-11-04 12:56:19 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2007 |
| | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING |
| | CODE |
| | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007 |
| | FAC FLORIDA ADMINISTRATIVE CODE |
| | FS FLORIDA STATUTE |
| | |
| | 1. THIS PROJECT IS A CHANGE OF OCCUPANCY IN ADDITION TO |
| | A LEVEL 3 ALTERATION, FBC EB 202 (AUTO REPAIR IS S1, |
| | FBC311). PLEASE NOTE ON THE PLAN AND CHECK FOR |
| | COMPLIANCE WITH FBC EB CHAPTER 9. |
| | |
| | 2. SEPARATE PERMIT REQUIRED FOR TANK REMOVAL AND |
| | REPLACEMENT. |
| | |
| | 3. ENTRY DOOR IS TO MEET THE REQUIREMENT OF |
| | FBC11-4.13.11(2) (OPENING FORCE 8.5LBF). |
| | |
| | 4. SEE FBC1004.1 AND DEFINITION OF FLOOR AREA, GROSS |
| | FBC 202. MAXIMUM AREA PER OCCUPANT AS PER TABLE |
| | 1004.1.1 IS 30SF; BASED ON TOTAL SQUARE FEET AREA, |
| | OCCUPANT LOAD SHOULD BE 56 IF ENTIRE SPACE IS |
| | CLASSIFIED AS MERCANTILE, SINGLE OCCUPANCY. |
| | |
| | 5. SEE COMMENT 5; IF OCCUPANT LOAD IS GREATER THAN 50, |
| | TWO INDEPENDENT EXITS REQUIRED FBC1015. |
| | |
| | 6. A SHUTTER STORAGE AREA IS SHOWN. THIS IS ACCEPTABLE, |
| | BUT NOTE THAT ALL GLAZED PRODUCTS ARE IMPACT RATED |
| | (ADVISORY ONLY). EXIT DOORS ARE REQUIRED TO BE IMPACT |
| | FBC1003.6. |
| | |
| | 7. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR |
| | THE A/C STANDS, FAC9B72. PLEASE HAVE THIS REVIEWED BY |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL FBC*106. |
| | |
| | 8. THIS REVIEW CAN BE PASSED WITH PROVISO (REVISION |
| | REQUIRED) UPON REQUEST OF ARCHITECT IF ALL OTHER TRADES |
| | PASS REVIEW. PLEASE CONTACT ME FOR FURTHER ASSISTANCE. |
| | |
| | |