Plan Review Notes
Plan Review Notes For Permit 09100440
Permit Number 09100440
Review Stop B
Sequence Number 1
Notes
Date Text
2009-10-26 14:12:56BUILDING PLAN REVIEW
 PERMIT: 09100440
 ADD: 315 S FLAGLER
 CONT: J JAY ROTHE INC
 TEL: (561)389-4137
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
 OCT. 26/ 2009
  
 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER
 MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC
 BUILDING WITH 2009 SUPPLEMENTS.
  
 PLANS WILL ALSO BE REVIEWED TO THE 2007 EXISTING
 BUILDING CODE W/ 2009 SUPPLEMENTS, PLEASE INDICATE TO
 WHAT LEVEL ALTERATION WILL BE COMPLETED UNDER THIS
 PERMIT.
 401.4 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE
 OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 403, 404 AND 405 OF THIS CODE.
 PLEASE INDICATE THIS INFORMATION ON THE PLANS.
  
 2) THE PLANS DO NOT PROVIDE ENOUGH INFORMATION FOR A
 THROUGH REVIEW, PLEASE PROVIDE THE MINIMUM BUILDING
 TYPE. TABLE 503 & TABLE 601. I BELIEVE THIS IS A
 HIGHRISE BUILDING OF 11 STORIES OR MORE BEING
 CONSIDERED A TYPE 1-A BUILDING.
  
 3) SHEET A-1 DOES NOT PROVIDE ANY INFORMATION AS TO THE
 BUILDING USE OR OCCUPANCY, IT APPEARS TO BE A MIXED USE
 OCCUPANCY, IS THIS A NONSEPERATED OCCUPANCY IN
 COMPLIANCE WITH 508.3.2.1 OR SEPERATED OCCUPANCIES IN
 COMPLIANCE WITH 508.3.3.
  
 4) SHEET A-1 DOES NOT PROVIDE ANY INFORMATION ON THE
 NEW TENANT SEPERATION WALL/ CORRIDOR WALLS AND OR
 OPENING PROTECTIVES, PLEASE PROVIDE ADDITIONAL
 INFORMATION. FBC 708.1(7) & TABLE 715.4 OPENING
 PROTECTIVES.
  
 5) SHEET A-3 DETAIL B INDICATES THE USE OF WOOD
 BLOCKING, PLEASE SEE SECTION 603.1 FOR ALLOWABLE
 MATERIALS.
  
 6) SHEET A-1 INDICATES THE DRINKING FOUNTAIN HAS BEEN
 RELOCATED PLEASE PROVIDE THE WIDTH OF THE CORRIDOR AS
 WELL AS THE AT WHAT HEIGHT THE FOUNTAIN IS TO BE
 INSTALLED, PROVIDE BOTH THE TOP AND BOTTOM OF THE WATER
 FOUNTAIN. 1017.2 MINIMUM CORRIDOR WIDTH, 11-4.4.1
 PROTRUDING OBJECTS, & 11-4.15.5 CLEARENCES.
  
 7) IT APPEARS THERE IS A TYPO ON ALL THE SHEETS BEING
 THE ADDRESS AT 15 S FLAGLER, PLEASE CORRECT TO 315 S
 FLAGLER AND SUITE NUMBER .
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES
 DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER
 NOTICE.
  
 OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM
 - 5:00 PM.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  