| 2009-10-26 17:07:48 | BUILDING PLAN REVIEW |
| | PERMIT: 09100416 |
| | ADD: 22420 MEDINA WAY |
| | CONT: D & A BUILDERS |
| | TEL: (561)662-6226 |
| | |
| | FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| | W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | OCT. 26/ 2009 |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER |
| | MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC |
| | RESIDENTIAL WITH 2009 SUPPLEMENTS. |
| | |
| | PLANS WILL ALSO BE REVIEWED TO THE 2007 EXISTING |
| | BUILDING CODE W/ 2009 SUPPLEMENTS, PLEASE INDICATE TO |
| | WHAT LEVEL ALTERATION WILL BE COMPLETED UNDER THIS |
| | PERMIT. |
| | 401.4 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE |
| | OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO |
| | SECTIONS 403, 404 AND 405 OF THIS CODE. |
| | PLEASE UPDATE PLANS. |
| | |
| | 2) MISSING WIND DSIGN INFO: |
| | 1603.1.4 WIND DESIGN DATA./ R301.2.1.3 -R301.2.1.5 |
| | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL |
| | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE |
| | DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE |
| | BUILDING: |
| | 1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR |
| | (KM/HR). |
| | |
| | 2. WIND IMPORTANCE FACTOR, I W , AND BUILDING |
| | CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 |
| | AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. |
| | |
| | 3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS |
| | UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND |
| | DIRECTION SHALL BE INDICATED.PLEASE REVIEW SECTION |
| | R-3012.1.4(3) EXPOSURE "C" REQUIREMNTS. |
| | |
| | 4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF |
| | DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT. |
| | |
| | 5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES |
| | IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR THE SELECTION |
| | OF EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT |
| | SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN |
| | PROFESSIONAL. |
| | |
| | 3) PLANS A-02 ARE LACKING THE WIND DESIGN PRESSURE FOR |
| | THE NEW WINDOW OPENING AS WELL AS NEW DOUBLE EXTERIOR |
| | DOOR LOCATED IN STUDY. |
| | |
| | 4) THE NEW EXTERIOR DOUBLE DOOR OPENING AT THE STUDY |
| | ALSO IS MISSING PRODUCT APPROVALS REQUIRED BY RULE |
| | 9B-72(31)( A) AND R-301.2.1.2. |
| | |
| | 5) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE |
| | REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND |
| | APPROVED IN WRITTING BY THE DESIGNER OF RECORD PRIOR TO |
| | SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | |
| | 6) SHEET A-203 THE NEW MASTER BATHROOM AND WHIRLPOOL |
| | TUB IS LOCATED NEXT TO AN EXISTING WINDOW, THE NEW TUB |
| | HAS CREATED A HAZARDOUS LOCATION SEE R308.4(5). |
| | |
| | 7) SHEET A-01 INDICATES REMODELING OF THE RESTROOM |
| | UNDER THE STAIRWELL, PLEASE PROVIDE COMPLIANCE WITH |
| | R311.2.2 UNDER STAIR PROTECTION. ENCLOSED ACCESSIBLE |
| | SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR |
| | SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE |
| | WITH 1/2-INCH (13 MM) GYPSUM BOARD. |
| | |
| | 8) BUILDING PROVISO: THE NEW MASTER BEDROOM EGRESS |
| | WINDOW MUST MAINTAIN A CLEAR VENT SIZE OF 5.7 SQ FT, A |
| | 245 WINDOW MAY MAKE OR MAY NOT MAKE THE CLEAR REQUIRED |
| | VENT SIZE DEPENDING ON THE SASH SIZE! R310.1.1 |
| | R310.1.1 MINIMUM OPENING AREA. ALL EMERGENCY ESCAPE AND |
| | RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING |
| | OF 5.7 SQUARE FEET (0.530 M2). |
| | |
| | EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM |
| | NET CLEAR OPENING OF 5 SQUARE FEET (0.465 M2). |
| | |
| | R310.1.2 MINIMUM OPENING HEIGHT. THE MINIMUM NET CLEAR |
| | OPENING HEIGHT SHALL BE 24 INCHES (610 MM). |
| | |
| | R310.1.3 MINIMUM OPENING WIDTH. THE MINIMUM NET CLEAR |
| | OPENING WIDTH SHALL BE 20 INCHES (508 MM). |
| | |
| | STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES |
| | DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER |
| | NOTICE. |
| | |
| | OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM |
| | - 5:00 PM. |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE |
| | CUSTOMER SERVICE SURVEY AT: |
| | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| | |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |