2009-12-10 09:43:14***PROVISO****
 ISSUED AT CONTRACTOR'S RISK
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007 WITH 2009 SUPPLEMENTS
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 REVISE PLANS TO INCLUDE THE FOLLOWING INFORMATION:
  
 1. PROVIDE A SITE PLAN SHOWING LOCATION OF PROPOSED
 IMPROVEMENT IN RELATION TO THE PROPERTY LINE, FBC R301.
 A COPY OF A SURVEY WAS SUBMITTED. PLEASE SHOW LOCATION
 OF PROPOSED IMPROVEMENT AND INCLUDE "SUN DECK" WITH
 DIMENSIONS (OVERALL SIZE AND DISTANCE TO PROPERTY
 LINES).
  
 2. DECLARE WIND DESIGN CRITERIA FBC R 301; DECLARE WIND
 SPEED FBC R301.2.1 (MINIMUM 140MPH), EXPOSURE CATEGORY
 (APPEARS TO BE EXPOSURE C). ALSO PROVIDE BUILDING
 HEIGHT SO THAT COMPONENTS & CLADDING DESIGN PRESSURES
 CAN BE DETERMINED.
  
 3. INFORMATION REGARDING THE ROOF WAS NOT PROVIDED. IF
 THIS IS AN EXISTING ROOF, PLEASE NOTE ON PLANS.
  
 4. PROVIDE ELEVATION DESIGNATIONS (N,S,E OR W). PROVIDE
 COMPASS NORTH ON THE SITE PLAN. FBC*106, FBC301.
  
 5. HOW WILL THE BLOCK INFILL TIE IN STRUCTURALLY TO THE
 EXISTING? SEE FBC R301.1, ALL PARTS SHALL BE
 CONSTRUCTED TO SAFELY SUPPORT ALL LOADS.
  
 6. HOW HAVE YOU DETERMINED THAT THE FOOTER SIZE IS
 ADEQUATE?
  
 7. IMPACT FEES MAY BE DUE TO PALM BEACH COUNTY. THE
 PLANS MUST BE STAMPED AND THE RECEIPT (IF FEES ARE DUE)
 IS TO BE ATTACHED TO THE APPLICATION.
  
 8. WILL THIS AREA BE AIR CONDITIONED? ENERGY CALCS MAY
 BE REQUIRED FBC R11.
  
 9. PLEASE REVISE THE PLAN TO SHOW THAT THE MASTER
 BEDROOM EMERGENCY EGRESS IS NOT AFFECTED BY THE
 PROPOSED IMPROVEMENT, FBC R310 (YOU MAY DO THIS BY
 NOTING LOCATION OF MASTER BEDROOM EMERGENCY EGRESS ON
 THE PLAN).
  
 10. PHOTOGRAPHS WERE INCLUDED IN THE PLANS. SEE
 FBC*106, PLANS ARE TO BE ARCHITECTURAL QUALITY, TO
 SCALE. PHOTOGRAPHS SHOULD NOT BE USED TO SHOW CODE
 COMPLIANCE. PLEASE INCORPORATE ANY REQUIRED INFORMATION
 INTO THE PLAN.
  
 11.PORTIONS OF TWO DIFFERENT DOOR PRODUCT APPROVALS
 WERE PROVIDED. OTHER SHEETS STAPLED WITH THE ANCHOR
 EVALUATION REPORT WERE SPEC SHEETS FOR WINDOWS, DOORS,
 WINDOW INSTALLATION INFORMATION. PLEASE INCLUDE THE
 FLORIDA STATE PRODUCT APPROVAL COVER SHEET (SHOWS CODE
 VERSION, STATUS). FAC0B72. PLEASE PRINT THE COVER
 SHEET, EVALUATION REPORT, INSTALLATION INSTRUCTIONS FOR
 THE PRODUCT YOU WISH TO INSTALL. (PARTS OF FL8838,
 FL5262 INCLUDED, PLEASE SELECT ONE AND PRINT REQUIRED
 DOCUMENTS.)
  
  
  
  
  
  