| 2009-11-02 13:18:44 | BUILDING PLAN REVIEW |
| | PERMIT: 09100196 |
| | ADD: 1028 GREEN PINE BLVD # 0070 |
| | CONT: LIFETIME EXTERIORS |
| | TEL: (561)582-7101 |
| | |
| | FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| | W/ 2008 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW |
| | ACTION: DENIED |
| | |
| | 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER |
| | MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC |
| | BUILDING WITH 2009 SUPPLEMENTS. |
| | |
| | PLANS WILL ALSO BE REVIEWED TO THE 2007 EXISTING |
| | BUILDING CODE W/ 2009 SUPPLEMENTS, PLEASE INDICATE TO |
| | WHAT LEVEL ALTERATION WILL BE COMPLETED UNDER THIS |
| | PERMIT. |
| | 401.4 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE |
| | OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO |
| | SECTIONS 403, 404 AND 405 OF THIS CODE. |
| | |
| | 2) PLEASE PROVIDE A SITE PLAN INDICATING WHICH BUILDING |
| | AND UNIT WHERE THE WORK IS TO TAKE PLACE (WHICH SIDE OF |
| | THE BUILDING), THIS MAY EFFECT THE EXPOSURE CATEGORY, |
| | FBC BUILDING 1609.4. |
| | |
| | 3) PLANS FAIL TO INDICATE WIND DESIGN INFORMATION: |
| | 1603.1.4 WIND DESIGN DATA. |
| | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL |
| | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE |
| | DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE |
| | BUILDING: |
| | 3.1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR |
| | (KM/HR). |
| | |
| | 3.2. WIND IMPORTANCE FACTOR, I W , AND BUILDING |
| | CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 |
| | AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. |
| | |
| | 3.3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS |
| | UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND |
| | DIRECTION SHALL BE INDICATED. |
| | |
| | 3.4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF |
| | DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT. |
| | |
| | 3.5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES |
| | IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR THE SELECTION |
| | OF EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT |
| | SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN |
| | PROFESSIONAL. |
| | |
| | 4) DISCREPANCY PLEASE REVIEW DOOR HEIGTH, THE PLAN |
| | INDICATES THE DOORS TO BE 84" WHERE AS THE PRODUCT |
| | APROVAL (08-0213.03 ) DOOR HEIGTH IS HIGHLIGHTED OR |
| | INDICATES AS A 6'-8", PLEASE UPDATE PLEASE CORRELATE |
| | INFORMATION. |
| | |
| | 5) PLANS INDICATE THIS TO BE A SINGLE STORY BUILDING, |
| | AREN'T THE BUILDINGS IN THE NORTHWEST CORNER OF THE |
| | DEVELOPMENT 2 STORY STRUCTURES. 106.1.2 ADDITIONAL |
| | INFORMATION REQUIRED. |
| | |
| | 6) PRODUCT APPROVAL FL 6231-R3 PLEASE HIGHLITE WHICH OF |
| | THE WALL PANEL TYPES ARE GOING TO BE INSTALLED ON THIS |
| | PROJECT, PLEASE INDICATE WHAT TYPE OF STRUCTRUAL |
| | MEMBERS THE SLIDING GLASS DOORS AS WELL AS THE |
| | ACCORDIAN SHUTTERS ARE GOING TO BE ATTACHED TOO. |
| | |
| | STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES |
| | DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER |
| | NOTICE. |
| | |
| | OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM |
| | - 5:00 PM. |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE |
| | CUSTOMER SERVICE SURVEY AT: |
| | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| | |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |