| 2009-09-28 15:14:52 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST. |
| | 2007 FL. RESIDENTIAL CODE WITH 2009 REVISIONS. |
| | |
| | 1- FLAT ROOF NOA 07-1203.01 SUBMITTED WAS SUPERSEDED BY |
| | MIAMI-DADE COUNTY. SEE ATTACHED COPY FROM MIAMI-DADE |
| | COUNTY WEBSITE. NEED TO PROVIDE CURRENT NOA AND CLEARLY |
| | MARK SPECIFIC APPROVED ASSEMBLY AND BASE SHEET |
| | FASTENING OPTION TO BE INSTALLED TO VERIFY COMPLIANCE |
| | WITH THE DESIGN PRESSURES OF SEC. R301 OF 2007 FLORIDA |
| | RESIDENTIAL CODE. |
| | |
| | 2- PROVIDE NAIL ENHANCING CALCULATIONS (RAS 117 |
| | CALCULATIONS) AT PERIMETER AND CORNER AREAS AS REQUIRED |
| | BY GENERAL LIMITATION #7 ON NOA SUBMITTED TO RESIST THE |
| | UPLIFT LOADS OF SEC. R301 OF 2007 FLORIDA RESIDENTIAL |
| | CODE. |
| | |
| | 3- NAIL ENHANCING CALCULATIONS (RAS 117 CALCULATIONS) |
| | NEED TO BE SIGNED AND SEALED AS REQUIRED BY GENERAL |
| | LIMITATION #7 ON LAST PAGE OF NOA SUBMITTED. |
| | NOTE: DESIGN PROFESSIONAL DOING THE RAS 117 |
| | CALCULATIONS TO TAKE INTO CONSIDERATION THAT ACCORDING |
| | TO SEC. R301.2.1.4.3 OF 2009 REVISIONS TO THE 2007 |
| | FLORIDA RESIDENTIAL CODE, THIS BUILDING IS LOCATED ON |
| | EXPOSURE "C". |
| | |
| | 4- PERMIT VALUATION DECLARED IN THE PERMIT APPLICATION |
| | IS TOO LOW. THEREFORE OWES $73.11 FOR UPDATED PERMIT |
| | VALUATION AS REQUIRED BY SEC. 108.3 CITY AMENDMENTS TO |
| | FBC. |
| | |
| | 5- PROVIDE RECORDED NOTICE OF COMMENCEMENT AS REQUIRED |
| | BY SEC. 713.13 FLORIDA STATUTE. |
| | |
| | JULIO GOMEZ |
| | BUILDING PLANS EXAMINER |
| | (561)805-6712 |