| Plan Review Notes For Permit 09090423 |
| Permit Number |
09090423 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2009-09-24 17:56:26 | BUILDING PROVISO: | | | 1014.2 EGRESS THROUGH INTERVENING SPACES. | | | (2)MEANS OF EGRESS ARE NOT PROHIBITED THROUGH | | | STOCKROOMS IN GROUP M OCCUPANCIES WHEN ALL OF THE | | | FOLLOWING ARE MET: | | | | | | 2.1. THE STOCK IS OF THE SAME HAZARD CLASSIFICATION AS | | | THAT FOUND IN THE MAIN RETAIL AREA; | | | | | | 2.2. NOT MORE THAN 50 PERCENT OF THE EXIT ACCESS IS | | | THROUGH THE STOCKROOM; | | | | | | 2.3. THE STOCKROOM IS NOT SUBJECT TO LOCKING FROM THE | | | EGRESS SIDE; AND | | | | | | 2.4. THERE IS A DEMARCATED, MINIMUM 44-INCH-WIDE (1118 | | | MM) AISLE DEFINED BY FULL OR PARTIAL HEIGHT FIXED WALLS | | | OR SIMILAR CONSTRUCTION THAT WILL | | | MAINTAIN THE REQUIRED WIDTH AND LEAD DIRECTLY FROM THE | | | RETAIL AREA TO THE EXIT WITHOUT OBSTRUCTIONS. | | | |
|