| Plan Review Notes For Permit 09090324 |
| Permit Number |
09090324 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2009-10-21 17:16:23 | DENIED | | | REFERENCE: | | | FBC-2007 RESIDENTIAL | | | FBC-2007 CHAPTER 1 (ADMIN) | | | | | | 1. SHT SITE-1 INDICATES THE WASH MACHINE WILL BE | | | RELOCATED TO NEW LAUNDRY ROOM. PER SECTION | | | 106.3.5.1.4(9) A SANITARY RISER DIAGRAM IS REQUIRED. | | | PLEASE SUBMIT A SANITARY RISER DIAGRAM SHOWING ALL PIPE | | | SIZES, TRAPS, STANDPIPES & VENTS PER SECTIONS 3005, | | | 3101, 3201. 3" PIPE IS REQUIRED FOR THE BRANCH LINE & | | | STACK FOR THE AUTOMATIC WASH MACHINE. SECTION 406.3. | | | | | | 2. MORE INFORMATION IS REQUIRED. PLEASE SHOW THE | | | LOCATION OF THE WASH MACHINE ON THE EXISTING FLOOR | | | PLAN. SECTION 106.1.2. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|