2009-09-03 16:59:34BUILDING PLAN REVIEW
 PERMIT: 09090065
 ADD: 8537 NORTHLAKE BLVD
 CONT: "TO BE DETERMINED"
 TEL: (561)494-1088 DANIEL ROBERGE
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
 SEPTEMBER 03/2009
  
 1) A LICENSECED CONTRACTOR IS TO BE SIGNED ON FOR THE
 SCOPE OF WORK COVERED BY THEIR LICENSE. FL S S 489.
  
 2) PLANS ARE INDICATED TO BE DESIGNED BY P.E. DANIEL
 ROBERGE, PLANS, SPECIFICATIONS, REPORTS OR OTHER
 DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND BEING
 FILED FOR PUBLIC RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED TO THE
 DOCUMENT. FL ADMIN CODE 61G15-23.002 ENGINEERS.
  
 3) PERMIT APPLICATION UNDER DESCRIPTION OF WORK
 INDICATES THE ONLY WORK TO BE COVERED UNDER THIS PERMIT
 IS THE NEW RESTROOMS. SHEET 6 INDICATES A THATCHED
 CHICKEE AND SHEET 7 INDICATES NEW KIOSK. ARE THESE
 STRUCTURES ALSO TO BE INCLUDED WITHIN THE SCOPE OF THIS
 PERMIT? ADDITIONAL INFORMATION REQUIRED 106.1.2.
 PLEASE NOTE THE ONLY EXEMPTION TO THE CHICKEE NOT
 REQUIRING PERMITTING IS UNDER 102.2(H) CHICKEES
 CONSTRUCTED BY THE MICCOSUKEE TRIBE OF INDIANS OF
 FLORIDA OR THE SEMINOLE TRIBE OF FLORIDA.
  
 4) THE ELEVATIONS ON SHEET 9 &10 INDICATE THE USE OF A
 BOND BEAM CONSTRUCTION, THE WAY THE ELEVATION APPEARS
 THE INTENT IS TO USE STEEL POWER LINTELS INSTEAD OF A
 PRECAST CONCRETE LINTEL, PLEASE PROVIDE THE
 MANUFACTURES SPEC FOR STEEL LINTEL. 106.1.2 ADDITIONAL
 INFORMATION REQUIRED.
  
 5) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING,
 PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING
 REPORTS ARE AS FOLLOWS:
 5A ) GLASS BLOCK
 5B) EXTERIOR SWING DOORS
 5C) WALL LOUVERS- CONCRETE
 5D) LINTELS
 5E) TRUSS ANCHORS
 F) ROOF ASSEMBLIES
 G) SKYLIGHTS- LARGE MISSILE TESTED GLAZED OPENING!
  
 6) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE
 REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITTING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 7) 1609.1.4 PROTECTION OF OPENINGS IN WIND-BORNE DEBRIS
 REGIONS, EXTERIOR GLAZING THAT RECEIVES POSITIVE
 PRESSURE IN THE LOWER 60 FEET (18.3 M) IN BUILDINGS
 SHALL BE ASSUMED TO BE OPENINGS AND THE BALANCE OF
 GLAZED OPENINGS IN THE REST OF THE BUILDING SHALL BE
 ASSUMED TO BE ZERO UNLESS SUCH GLAZING THAT RECEIVES
 POSITIVE PRESSURE IS IMPACT RESISTANT OR PROTECTED WITH
 AN IMPACT RESISTANT COVERING MEETING THE REQUIREMENTS
 OF SSTD 12, ASTM E 1886 AND ASTM E 1996, OR MIAMI-DADE
 TAS 201, 202 AND 203 REFERENCED THEREIN AS FOLLOWS: 1.
 GLAZED OPENINGS LOCATED WITHIN 30 FEET (9.1 M) OF GRADE
 SHALL MEET THE REQUIREMENTS OF THE LARGE MISSILE TEST.
 2. GLAZED OPENINGS LOCATED MORE THAN 30 FEET (9.1 M)
 ABOVE GRADE SHALL MEET THE PROVISIONS OF THE SMALL
 MISSILE TEST.
  
 STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES
 DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER
 NOTICE.
  
 OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM
 - 5:00 PM.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
 SURVEY:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved