| Date |
Text |
| 2009-08-20 08:26:51 | BUILDING PLAN REVIEW |
| | PERMIT: 09080335 |
| | ADD: 222 LAKEVIEW AV# 100 |
| | CONT: MENEMSHA DEVELOPMENT |
| | TEL: (718)337-9012X247 |
| | FL BLD CODE= 2074 FLORIDA BUILDING CODE |
| | W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | AUGUST 20/2009 |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1)PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER |
| | MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC |
| | BUILDING WITH 2009 SUPPLEMENTS. |
| | |
| | PLANS WILL ALSO BE REVIEWED TO THE 2007 EXISTING |
| | BUILDING CODE W/ 2009 SUPPLEMENTS, PLEASE INDICATE TO |
| | WHAT LEVEL ALTERATION WILL BE COMPLETED UNDERTHIS |
| | PERMIT. |
| | 401.4 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE |
| | OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO |
| | SECTIONS 403, 404 AND 405 OF THIS CODE. |
| | |
| | 2) SHEET A.0 / CODE DATA & CORRECTIONS; |
| | 2A) LOCATION OF PROJECT, WEST PALM BEACH, FL |
| | |
| | 2B) CONSTRUCTION TYPE: TYPE I-A NOT A V-B |
| | |
| | 2C) BUILDING HEIGHT NOT A MULTI-STORY BUT HIGHRISE |
| | SECTION 403 |
| | |
| | 2D) FIRE RESISTANCE RATINGARE LISTED FOR A V-B CORRECT |
| | TO A TYPE I-A |
| | |
| | 3) SHEET A3.0 |
| | |
| | 3A) DETAIL# 4 INDICATES THE USE OF PLYWOOD BLOCKING |
| | BETWEEN STUDS. PLEASE REVIEW 603.3.1.1USE OF FIRE |
| | RETARDANT TREATED WOOD (11) BLOCKING. |
| | |
| | 3B) DETAIL# 5 INDICATESTHE USE OF WOOD STUDS, |
| | 603.1.1(1.1) |
| | |
| | 4) SHEET A3.3 DETAILS 3&4 INDICATE THE USE OF 1/2" |
| | PLYWOOD PANEL LAMINATES PLEASE REVIEW 803.4.1, 803.4.2 |
| | & 803.4.4.PLEASE PROVIDE COMPLIANCE WITH ONE OF THESE |
| | SECTIONS. |
| | |
| | 5) ATM MACHINES INDICATE ON SHEET A1.0 COMMENT NUMBER |
| | 42 ATM TO BE REMOVED AND OR RELOCATED, SHEET A1.1 |
| | DETAIL 5G&H/ A3.1 INDICATES THE WIDTH OF THE MACHINE. |
| | BETWEEN DETAILS A&B IT INDICATES THE MACHINES ARE ADA |
| | COMPLIANT, PLEASE PROVIDE THE HEIGHT OF |