| 2009-08-11 12:14:55 | BUILDING PLAN REVIEW |
| | PERMIT: 09080114 |
| | ADD: 223 CLEMATIS ST. |
| | CONT: PAUL DAVIS CONSTRUCTION |
| | TEL: (561)718-8161 |
| | |
| | FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| | W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | AUGUST 11/2009 1ST REVIEW |
| | |
| | BUILDING PROVISO: |
| | |
| | 1) PLANS INDICATE A TRAVEL DISTANCE OF 75'-6" FROM THE |
| | BOOTH FURTHEST FROM THE ENTRY AND CHOICE OF TO MEANS OF |
| | EGRESS, PLEASE SUBMIT A REVISION COMPLYING WITH: |
| | 1014.4.3.3 TABLE AND SEATING AISLE ACCESS WAY LENGTH. |
| | THE LENGTH OF TRAVEL ALONG THE AISLE ACCESS WAY SHALL |
| | NOT EXCEED 30 FEET (9144 MM) FROM ANY SEAT TO THE POINT |
| | WHERE A PERSON HAS A CHOICE OF TWO OR MORE PATHS OF |
| | EGRESS TRAVEL TO SEPARATE EXITS. |
| | |
| | 2) GENERAL NOTE# 11 INDICATES THAT CONTRACTOR TO SUBMIT |
| | TO THE ARCHITECT OF RECORD DOCUMENTATION FOR FLAME |
| | SPREAD AND SMOKE DEVELOPMENT ON DRAPERIES, SEATING |
| | (BUILT INS) AND OTHER ITEMS BEFORE SUBMITTAL TO THE |
| | BUILDING DEPARTMENT. |
| | |
| | 3) GC TO PROVIDE AN INCRASED VALUE FOR BUILT INS. |
| | |
| | |
| | JIM WITMER C. B. O. |