2010-04-21 11:59:55BUILDING PLAN REVIEW
 PERMIT: 09070775
 ADD: 4295 45TH ST
 CONT: TO BE DETERMINED
 TEL: (561)856-6655 NEYITA LEIVA
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 APRIL 21/ 2010
  
 ACTION: DENIED
  
 ONCE TTHE CONTRACTOR HAS SIGNED ON, LICENSURE CAN BE
 VERIFIED AND PERMIT VALUATION IS VERIFIED THEN A PASS
 CAN BE ENTERED.
  
 1-4) COMPLIED.
  
 5) PROVISO: ADDITION IS LOCATED WITHIN A FLOODZONE A8
 AT WITH A REQUIRED ELEVATION OF 15.5 FT NGVD, FBC
 BUILDING 3110.1.2 / CITY OF WPB CODE OF ORDINANCES
 SECTION 94-546. STRUCTURE IS LOCATED IN AN "A" FLOOD
 ZONE. A FLOOD ELEVATION CERTIFICATE WILL BE REQUIRED
 ONCE THE FLOOR SLAB HAS BEEN POURED.
  
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISION, DOCUMENTS
 THAT ARE BEING PROVISOED, WILL REQUIRE ADDITIONAL
 REVIEWS WITH ASSOCIATED FEES.
  
  
 6) BUILDING PROVISO:FL BLD CODE 1609.6.2.2 COMPONENTS &
 CLADDING, PROVIDE 2 COPIES, 3 IF THRESHOLD OR RESIDENT
 INSPECTOR OF PRODUCT TESTING REPORTS, MISSING REPORTS
 ARE AS FOLLOWS:
 A-F) COMPLIED.
 G) ROOFING ASSEMBLIES INCLUDING ROOF INSULATION-
 SUBMITTED WAS CARLISLE ROOF DECK NOA 08-0108.09
 NO SUB-SYSTEM WAS HIGHLIGHTED, ALL SYSTEMSWILL REQUIRE
 ENHANCED FASTENING.
 PAGE 17- STEEL DECK SYSTEM LIMITATION, NOTE# 2 INDICATE
 BAR JOIST SPACING A MAXIMUM OF 5'-0". BAR JOIST J1 & J2
 ARE APPROXIMATELY 5'-10" C/C AND BAR JOIST J4 ARE
 APPROXIMATELY 5'-6" C/C/. WILL REQUIRE A DIFFERENT
 SYSTEM.
  
 H) ROOF TOP PENBARRY ALUMINUM FANS NOA: 09-1015.03
 +/-V50 PSF FANS ARE LOCATED IN ZONES 2 AAND ZONE 3 OF
 ROOF WITH DRAMATICLLY HIGHER PRESSURES.
  
 7-9) COMPLIED.
  
 10) IMPACT FEES PAID PR# 2010-0419-215
 11) COMPLIED.
  
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
 SURVEY:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved