| 2009-09-22 12:29:21 | PLAN COMMENTS FROM ENGINEERING 09-08-09 - STATUS IS |
| | FAILED |
| | SOME OF THE ISSUES HAVE BEEN DISCUSSED VIA PHONE |
| | CONVERSATIONS. |
| | |
| | #1 PROVIDE FFE EL OF SAM'S STORE AND MC DONALDS |
| | #2 REMOVE DOOR CHART SCHEDULE ON TOPOGRAPHIC SHEET (NOT |
| | NEEDED) |
| | #3 PROVIDE WRITTEN EXPLANATION FOR DRAINAGE PORTION |
| | (EXISTING DRAINAGE) WHICH DOES NOT FALL WITHIN |
| | PROPERTY. |
| | (IS THERE A DRAINAGE EASEMENT OR CROSS ACCESS EASEMENT? |
| | ETC..) |
| | #4 RETENTION POND NEXT TO SAM'S BUILDING IS FOR SAM'S |
| | USE ONLY? |
| | #5 SODDING NOTES NEED TO BE ON SHEET 6030, ITS PART OF |
| | EROSION CONTROL. |
| | #6 CHECK NEW SWALE IN THE BACK, IT MAY NEED A HAND RAIL |
| | DUE TO THE SLOPES. |
| | #7 FIRE SERVICE WILL STILL BE SUFFICIENT TO SERVE NEW |
| | ADDITIONAL S.F. |
| | #8 DOMESTICS SERVICE AND FIRE SERVICE BACKFLOWS MUST BE |
| | TO UNIVERSITY OF SOUTHERN CALIFORNIA APPROVED LIST. |
| | #9 PROVIDE DETAIL FOR A TYPE F DITCH BOTTOM INLET. |
| | #10 SEWER CLEAN-OUT NEEDED EVERY 75' , SEE PLAN |
| | #11 PROVIDE INVERT AT EXISTING SEWER LATERAL |
| | #12 HYDRANT SHOWN ON-SITE OFF CITY'S WM NEEDS A DCDA |
| | (SHT. 6060) |
| | #13 SEWER FLOWS SOUTH TO LIFT STATION (SHT. 6060) |
| | #14 S2 IS CALLING OUT MANHOLE WHEN IT SHOULD BE GREASE |
| | INTERCEPTOR |
| | #15 OUR STANDARD GREASE INTERCEPTOR IS NOT UP TO CODE. |
| | PROVIDE SHOP DRAWING. |
| | #16 S1 AND S2 CALL OUT SHEET XXXX, STATE SHEET NUMBER. |
| | #17 WATER SERVICE MUST HAVE THE REQUIRED DEPT. PLEASE |
| | CHECK GRADES AND DEPTH. 30" MIN DEPTH. |
| | #18 LARGE TREES ALONG CITY'S UTILITY EASEMENT ARE NOT |
| | ALLOWED. THERE IS WATER AND SEWER ALONG THESE |
| | EASEMENTS. ROOT BARRIER WILL BE REQUIRED FOR ANY |
| | VEGETATION ON THIS EASEMENT. |
| | #19 ALL ACCESS OFF 45TH STREET MUST MEET ADA. |
| | #20 SUPPLY COMMENTS FROM SFWMD AS ADVISED. |
| | |
| | COMMENTS SPECIFIC TO ENGINEERING HAVE BEEN REMOVED FROM |
| | LIST. |
| | |
| | MANUEL JULIAN GONZALEZ |
| | ENGINEERING PROJECT COORDINATOR |
| | ENGINEERING SERVICES DEPARTMENT |
| | 401 CLEMATIS STREET, 4TH FLOOR |
| | WEST PALM BEACH, FL 33401 |
| | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) |
| | MAIN PHONE: (561) 822-1200 |
| | DIRECT: (561) 494-1085 |
| | FAX: (561) 494-1116 |
| | MOBILE: (561) 644-7301 |
| | EMAIL: [email protected] |
| | WWW.WPB.ORG/ENGINEERING |
| | |