Notes
Date Text
2009-07-14 16:58:17 
  
 SEPARATE PLUMBING PERMIT AND PLANS ARE REQUIRED.
 *****I N C L U D I N G*****
  
 A. SUBMIT A SANITARY ISOMETRIC RISER DIAGRAM SHOWING
 ALL PIPE SIZES, TRAPS & VENTS PER SECTIONS 701.1, 901.1
 & 1001.1.
 B. SUBMIT A WATER ISOMETRIC RISER DIAGRAM SHOWING ALL
 PIPE SIZES, VALVES & (WHERE REQUIRED BY SECTION 604.9)
 WATER HAMMER ARRESTORS. SECTION 601.1.
 C. PER TABLE 403.1 A DRINKING FOUNTAIN IS REQUIRED.
 SHOW THE REQUIRED DRINKING FOUNTAIN ON THE FLOOR PLAN
 AND SUBMIT A DETAIL SHOWING COMPLIANCE WITH SECTION
 11-4.15 WITH ALL SUBSECTIONS AS WELL AS SECTION
 11-4.1.3(10(A) PROVISIONS FOR THOSE WHO HAVE DIFFICULTY
 BENDING OR STOOPING.
  
 ALL INFORMATION IS REQUIRED PRIOR TO STARTING ANY
 PLUMBING WORK.
  
  