| 2009-11-16 11:23:11 | BUILDING PLAN REVIEW |
| | PERMIT: 09060761 |
| | ADD: 2400 N FLAGLER DRIVE |
| | CONT: OCEAN GATE G.C. |
| | TEL: (561)644-7446 |
| | |
| | FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| | W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | 2ND REVIEW |
| | ACTION: DENIED |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE AND REPLACEANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER |
| | MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC |
| | BUILDING WITH 2009 SUPPLEMENTS, THE ONLY REFERENCE TO |
| | THE 2007 FBC IS FOUND ON A6 IN REFERENCE TO WIND |
| | DESIGN, NOWHERE IS FOUND THE 2009 SUPPLEMENTS. |
| | |
| | 2) SECOND REQUEST, NO PLANS WERE SUBMITTED FOR THE |
| | STRUCTURAL DESIGN OF THE PICNIC NOR TENNIS SHELTER.THE |
| | PERMIT APPLICATION INDICATES "WITH SELECTED SITE |
| | IMPROVEMENTS, IS THIS INCLUDED?????? |
| | PLANS ARE NOT CLEAR AS TO THE NATURE OF WORK. FOR |
| | EXAMPLE THE PERMIT APPLICATION INDICATES PICNIC |
| | SHELTERS AND TENNIS SHELTERS. |
| | SHEET LS-3 INDICATES POLIGON SHELTERS 20'X20' OR |
| | 22'X22' |
| | SHEET LD-2 INDICATES A 16'-8" X 16'-8" SHELTERS |
| | ARE BOTH OF THESE TO BE PICNIC SHELTERS? THERE IS NO |
| | DESIGN CRITERIA PROVIDED AT THIS TIME THE PLANS |
| | INDICATE "SUBJECT TO ONGOING DESIGN REVIEW. |
| | |
| | INFORMATIONAL 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 |
| | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN |
| | THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF |
| | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY |
| | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE |
| | SPECIFIC TO THE TECHNICAL CODES .CONSTRUCTION DOCUMENTS |
| | SHALL BE SUFFICIENT CLARITY TO INDICATE THE LOCATION, |
| | NATURE AND EXTENT OF THE WORK PROPOSED AND SHOW IN |
| | DETAIL THAT IT WILL CONFORM TO THE PROVISIONS OF THIS |
| | CODE AND RELEVANT LAWS, ORDINANCES, RULES AND |
| | REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL. |
| | |
| | 3)SECOND REQUEST, NO PLANS WERE SUBMITTED FOR THE |
| | STRUCTURAL DESIGN OF THE PICNIC NOR TENNIS SHELTER. THE |
| | PERMIT APPLICATION INDICATES "WITH SELECTED SITE |
| | IMPROVEMENTS, IS THIS INCLUDED?????? |
| | |
| | THE SAME IS TRUE FOR THE TENNIS SHELTERS FOUND ON SHEET |
| | LD-1" SUBJECT TO ONGOING DESIGN REVIEW". INFORMATIONAL |
| | 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 DRAWINGS & |
| | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM |
| | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, |
| | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE |
| | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC TO |
| | THE TECHNICAL CODES .CONSTRUCTION DOCUMENTS SHALL BE |
| | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND |
| | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT |
| | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS |
| | DETERMINED BY THE BUILDING OFFICIAL. |
| | |
| | 4)THE SAME ELECTRIC SHEETS ARE IN PLANS, 2ND REQUEST.. |
| | SHEET E-5 INDICATES THE LIGHT POLES TO BE USED ON THE |
| | PROJECT, THE WIND INFORMATION IS PROVIDED FOR 140 MPH |
| | BUT THE EXPOSURE IS NOT PROVEDED. THIS LOCATION SHALL |
| | BE CONSIDERED A "C" ZONE HAS THAT EXPOSURE FACTOR BEEN |
| | INCLUDED INTO THE POLE AND LIGHT FIXTURE DESIGN. ASCE |
| | 7-05. |
| | |
| | 5) THE SAME ELECTRIC SHEETS ARE IN PLANS. SHEET E-6 |
| | DOES INDICATE LIGHT POLE FIXTURE TYPES BUT THE EPA FOR |
| | FIXTURE TYPE WAS NOT PROVIDED. 106.1.2 ADDITIONAL |
| | INFORMATION REQUIRED./ ASCE 7-05. |
| | |
| | 6) 2ND REQUEST. SHEET LS-3 INDICATES THERE TO BE A |
| | NAUTICAL PLAYGROND. PLEASE REVIEW THE "GUIDE TO ADA |
| | ACCESSIBILITY GUIDELINES FOR PLAY AREAS" FOR ACCESSIBLE |
| | ROUTE, PLAY COMPONENTS, GROUND LEVEL AND ELEVATED PLAY |
| | COMPONENTS BASED ON TABLE 15.6.2.2. |
| | |
| | 7) NEW RESTROOM BUILDING: |
| | 7.1-7.4 COMPLIED. |
| | |
| | 5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES |
| | IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR THE SELECTION |
| | OF EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT |
| | SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN |
| | PROFESSIONAL. THE ELEVATION NOR SHEET A6 INDICATE THE |
| | PRESSURES FOR WALL OPENINGS NOR WIND PRESSURES FOR |
| | ZONES 1,2 & 3. |
| | |
| | 8) PLEASE PROVIDE ORIGINAL SIGNED AND SEALED SOILS |
| | REPORT. 1802.2.1 QUESTIONABLE SOIL. WHERE THE |
| | SAFE-SUSTAINING POWER OF THE SOIL IS IN DOUBT, OR WHERE |
| | A LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED IN THIS |
| | CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL REQUIRE |
| | THAT THE NECESSARY INVESTIGATION BE MADE. SUCH |
| | INVESTIGATION SHALL COMPLY WITH THE PROVISIONS OF |
| | SECTIONS 1802.4 THROUGH 1802.6 . |
| | |
| | 9) COMPLIED. |
| | |
| | 10) COMPLIED |
| | |
| | 11)BUILDING PROVISO: BUILDING APPROVED WITH EXCEPTION! |
| | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| | ASSESSMENT OF RE-INSPECTION FEE(S). |
| | |
| | FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, PROVIDE 2 |
| | COPIES OF PRODUCT TESTING REPORTS, MISSING REPORTS ARE |
| | AS FOLLOWS: |
| | 11A) TRUSS ANCHORS |
| | 11B) GLASS BLOCK |
| | 11C) LOUVERS |
| | 11D) EXTERIOR SWING DOORS |
| | 11E) ROOFING ASSEMBLIES |
| | 111F) ROOF TOP VENT |
| | |
| | 12) BUILDING PROVISO: WPB ADMIN CODE 106.3* PRODUCT |
| | APPROVALS. THOSE PRODUCT WHICH ARE REGULATED BY DCA |
| | RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY |
| | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL. |
| | |
| | 13) ONCE SQ FT AREAS OF PAVILIONS ARE KNOWN STATE RADON |
| | FEES WILL BE ASSESSED. |
| | |
| | NEW COMMENT: FOUND ON C1.1 THERE IS A ACCESSIBLE RAMP |
| | THAT PROVIDES ACCESS TO THE RESTROOMS, THE DESIGN |
| | INDICATED IS TO THE FDOT STANDARD, NO SECTIONS ARE |
| | PROVIDED FOR THIS ACCESS RAMP, NO BOTTOM LANDING. THE |
| | PLANS SHALL BE DESIGNED TO THE FLORIDA BUILDING CODE |
| | CHAPTER 11, SECTION 8.1 THROUGH 8.8. THERE ARE NO |
| | DETAILS FOUND ON ANY ARCHITECTURAL PLANS. |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | SURVEY: |
| | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | |