| Plan Review Notes For Permit 09060596 |
| Permit Number |
09060596 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2009-06-24 10:14:34 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. PLEASE ADVISE AS TO HOW THE ENGINEER HAS DETERMINED | | | THAT THE BUILDING HEIGHT IS 90'. THIS IS A MINIMUM OF A | | | TEN STORY BUILDING; TYPICALLY DESIGN IS FOR A MINIMUM | | | OF 10' PER STORY. |
|