2009-06-23 12:33:33BUILDING PLAN REVIEW
 PERMIT: 09060185
 ADD: 222 LAKEVIEW AVE SUITE# 110
 CONT: G3 CONSTRUCTION
 TEL: (561)445-3769
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER
 MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC
 BUILDING WITH 2009 SUPPLEMENTS.
  
 2) SHEET A1.1 INDICATES A NEW TENANT SEPERATION WALL/
 CORRIDOR TO BE 1 HR RATED AS PER 708.1 (7), THE PLANS
 ARE MISSING THE RATING OF THE TENANT ENTRY DOOR# 1 AND
 THE SIDELIGHTS
 SEE A3.1 THE DOOR SCHEDULE IS MISSING OPENING
 PROTECTIVES PER TABLE 715.4.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]