| 2009-08-07 11:33:07 | BUILDING PLAN REVIEW |
| | PERMIT: 09060175 |
| | ADD: 1302 PARKER AVE |
| | CONT: PLAN REVIEW/ TBA |
| | TEL: (561)706-0429 / ALBERT MARINCLLO |
| | |
| | FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| | W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | AUGUST 07/2009 |
| | 2ND REVIEW |
| | ACTION: DENIED |
| | |
| | 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER |
| | MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC |
| | BUILDING WITH 2009 SUPPLEMENTS. |
| | |
| | 2) PLANS ARE CURRENTLY IN AS A PLAN REVIEW, BUT WHEN |
| | THEY ARE SUBMITTED FOR PERMIT, THEY WILL NEED TO BE |
| | SIGNED AND SEALED. |
| | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS |
| | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR |
| | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE |
| | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. |
| | FL ADMIN CODE 61G15-23.002 ENGINEERS |
| | FL ADMIN CODE 61G16.003 ARCHITECTS |
| | |
| | 3) COMPLIED. |
| | |
| | 4) 2ND REQUEST, SHEET GC-503 GENERAL NOTE# 2 INDICATES |
| | A SOILS REPORT BY DUNKLEBURGER ENGINEERING AND TESTING |
| | WAS COMPLETED JULY 16, 2008, PLEASE SUPPLY (2) RAISED |
| | SEAL ORIGINALS. |
| | |
| | 5) 2ND REQUEST, THERE ARE STRUCTURES FOUND ON THIS |
| | SHEET STRUCTUREE WITH WEIR AS WELL AS HANDRAILS, |
| | ALTHOUGH THE WEIR WILBE LOW GRADE THE HANDRAIL WILL BE |
| | ABOVE GRADE AND SUBJECT TO WIND. SHEET GC-502 DOES NOT |
| | INDICATE WIND DESIGN CRITERIA:1603.1.4 WIND DESIGN |
| | DATA. SHEET E-501 ALSO HAS LIGHT POLES THAT WILL NEED |
| | TO HAVE WHAT WIND DESIGN CRITERIA WOULD HAVE BEEN USED |
| | IN CALCULATING IF THEY WILL WITHSTAND 140 MPH WIND, IF |
| | DERATING FACTORS WERE USED. |
| | |
| | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL |
| | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE |
| | DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE |
| | BUILDING: |
| | 1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR |
| | (KM/HR). |
| | |
| | 2. WIND IMPORTANCE FACTOR, I W , AND BUILDING |
| | CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 |
| | AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. |
| | |
| | 3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS |
| | UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND |
| | DIRECTION SHALL BE INDICATED. |
| | |
| | 4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF |
| | DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT. |
| | |
| | |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | SURVEY: |
| | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |